                 9

AIR INTAKE FILTER:  This filter 

is designed to clean air coming 

into  the  pump.    To  ensure  the 

pump  continually  receives  a 

clean,  cool,  dry  air  supply  this 

filter must always be clean and 

ventilation  opening  free  from 

obstructions.  Replace filter when 

necessary.

AIR COMPRESSOR PUMP:  To 

compress air, the pistons move 

up  and  down  in  the  cylinders.  

On the downstroke, air is drawn 

in through the air intake valves 

while the exhaust valves remain 

closed.  On the upstroke, air is 

compressed, the intake valves 

close  and  compressed  air  is 

forced out through the exhaust 

valves, into the discharge line, 

through the pilot valve and into 

the air tank.

PILOT VALVE:  When the toggle 

is in the upright position, all air 

from the air compressor is vented 

through  the  discharge  muffler.  

This gives an easy start feature.  

For normal operation, the toggle 

is in the 90° position.

SAFETY  RELIEF  VALVE:  

This  valve  is  designed  to  

prevent  system  failures  by  

relieving  pressure  from  the 

system  when  the  compressed 

air  reaches  a  predetermined 

level.    The  valve  is  preset  by 

the  manufacturer  and  must 

not  be  modified  in  any  way.  

To  verify  the  valve  is  working  

properly, pull on the ring.  Air pres-

sure should escape.  When the 

ring is released, it will reseat.  

AIR  TANK  DRAIN  VALVE:  

The  drain  valve  is  used  to  

remove  moisture  from  the 

air tank(s) after the air com-

pressor  is  shut  off.   

NEVER  

attempt  to  open  the  drain 

valve  when  more  than  10 

PSI of air pressure is in the 

air tank! 

 To open the drain 

valve, turn the knob counter-

clockwise.  
AIR  TANK  PRESSURE 

GAUGE:    The  air  tank  

pressure gauge indicates the 

reserve air pressure in the air 

tank (s).

PRESSURE  REGULATOR:  

The air pressure coming from 

the air tank is controlled by the 

regulator knob.  Turn the pres-

sure regulation knob clockwise 

to  increase  discharge  pres-

sure,  and  counterclockwise 

to  decrease  discharge  pres-

sure.

O U T L E T   P R E S S U R E 

GAUGE:  The outlet pressure 

gauge indicates the air pres-

sure available at the outlet side 

of the regulator.  This pressure 

is controlled by the regulator 

and is always less or equal to 

the air tank pressure.

OIL SIGHT GLASS:  The oil sight 

glass will register the amount of 

oil in the pump.   Ensure the oil 

level in the air compressor pump 

is adequate. If low, add SAE-30W 
non-detergent oil.

 

PC2017 FEATURES REVIEW

Содержание PC2017

Страница 1: ...tons Comments call SENCO s toll free Action line 1 800 543 4596 or e mail toolprof senco com OPERATING INSTRUCTIONS Document MTM011 Revised Date 062104 Replaces 07 10 03 Warnings for the safe use of this air compressor are included in this manual PC2017 Gasoline Air Compressor ...

Страница 2: ...OR FIRE 4 BURSTING 5 BREATHING 5 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 6 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 FEATURES DRAWING 8 FEATURES REVIEW 9 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 GASOLINE ENGINE 10 OPERATION 11 PRE START CHECKLIST 11 START UP 11 SHUTDOWN 11 MAINTENANCE 11 TROUBLESHOOTING 12 13 SPECIFICATIONS 15 WARRANTY 16 ...

Страница 3: ...PERSONAL INJURY TO THE OPERATOR INSPECTION Unbox the air compressor and write in the serial number in the space provided below Inspect for signs of obvious or concealed freight damage Be sure that all damaged parts are replaced and any mechanical problems are corrected prior to the operation of the air compressor SERIAL NUMBER_________________________________ If you have Questions or Comments call...

Страница 4: ...ver fill the engine fuel tank while the engine is running or hot Allow the engine to cool two minutes before refueling Do not refuel indoors or in a poorly ventilated area Always refuel slowly to avoid the possibility of spilled fuel which may cause a risk of fire Do not operate the unit if gasoline is spilled Wipe the air compressor clean and move it away from the spill Avoid creating any ignition ...

Страница 5: ...SK OF BURSTING SAFETY WARNINGS READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR Never inhale air from the air compressor either directly or from a breathing device connected to the air compressor This air compressor was designed for outdoor use Never operate this air compressor in an enclosed area Always make certain there is adequate ventilation fresh outside air for breathing and combustion ...

Страница 6: ...mals Never leave pressurized air compressor unattended Shut off air compressor and relieve pressure before attempting maintenance attaching tools or accessories Always maintain a safe distance from people and animals while operating the air compressor Do not move the air compressor while air tank is under pressure Do not attempt to move the air compressor by pulling on the hose SAFETY WARNINGS REA...

Страница 7: ...e thoroughly familiar with controls Do not operate air compressor without an air filter Do not operate air compressor in a corrosive environment Do not incline the air compressor transversely or longitudinally more than 10 Ensure the oil level is above the minimum notch and below the maximum notch on the dipstick If low add Senco part number PC0344 compressor pump oil Always operate the air compres...

Страница 8: ...8 Senco Gasoline Air Compressor Manual 2004 PC2017 GASOLINE AIR COMPRESSOR FEATURES PDAC046 062304 DLG ...

Страница 9: ...ed level The valve is preset by the manufacturer and must not be modified in any way To verify the valve is working properly pullonthering Airpres sure should escape When the ring is released it will reseat AIR TANK DRAIN VALVE The drain valve is used to remove moisture from the air tank s after the air com pressor is shut off NEVER attempt to open the drain valve when more than 10 PSI of air press...

Страница 10: ...ay be present A spark could cause an explosion or fire DANGER Do not smoke while fueling Do not fill fuel tank while compressor is running or hot Allow air compressor and engine to cool down for two minutes before refueling Do not fill fuel tank to point of overflowing Allow approximately 1 4 of head space for fuel expansion PREPARATION WARNING Always store fuel away from the air compressor while it i...

Страница 11: ...e air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the engine switch to the Off position Refer to the Engine Manual accompanying this unit 2 Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve rings 3 Once pressure in the air tanks register under 10 pounds open the drain valve under each air tank to ...

Страница 12: ...ef valve manually by pulling on ring If it still leaks it should be replaced Defective motor pressure switch Replace PROBABLE CAUSE Possible defective safety relief valve Excessive air tank pressure SYMPTOM 6 Air leak in air tank REMEDY Air tank must be replaced Do not attempt to repair air tank PROBABLE CAUSE Defective or rusted air tank SYMPTOM 4 Air leaks at pump PROBABLE CAUSE Defective gasket...

Страница 13: ...k and measure pump up time Compare to specifications If longer remove pump head and inspect valve plate clean or replace Clean or replace PROBABLE CAUSE Restricted air intake filter Defective reed valve Restriction in pilot valve SYMPTOM 9 Air compressor not making enough air REMEDY Clean or replace Do not incline the air compressor more than 10 in any direction while running Drain oil Refill to prop...

Страница 14: ...14 Senco Gasoline Air Compressor Manual 2004 Notes ...

Страница 15: ... Flywheel 10 Lubrication Splash Oil Quantity 17 3 oz Oil Type Senco PC0344 Crankcase Cast Iron Bearings Ball Cylinder Cast Iron Valves Reed Single Head Aluminum Filter Canister Pilot Valve Setting Cut out 125 PSI Cut in 95 PSI Air Tank Capacity 8 Gallon Performance CFM Air Displacement 14 7 CFM 40 PSI 10 6 CFM 100 PSI 9 0 Maximum Pressure 125 PSI Pump up Time 0 125 PSI 54 seconds Recovery Time 95 ...

Страница 16: ... speeds or voltage electric units only improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation maintenance or repairs made by person s other than a Senco Authorized Warranty Service Center 6 The use of other than genuine Senco Repair Parts will void warrant...

Отзывы: