background image

12

 TROUBLESHOOTING

Symptom 1. Motor will not run or restart.

Symptom 2. Noisy operation.

Power cord not plugged in.

Motor/Pressure switch in “OFF” position.

Motor thermal overload switch has
tripped.

Fuse blown or circuit breaker has tripped.

Wrong gauge wire or length of extension
cord.

Air tank pressure exceeds motor/
pressure switch “cut-in” pressure.

Pressure release valve on motor/
pressure switch has not unloaded pump
head pressure.

Defective motor, motor capacitor, motor/
pressure switch, or check valve.

Loose motor pulley or pump flywheel.

Lack of oil in the pump.

Carbon deposits on pistons or valves.

Bearing, piston or connecting rod failure.

Plug cord into grounded outlet.

Move switch to “AUTO” position.

Turn air compressor off, wait until motor is cool, then press
motor thermal overload (red) button firmly until click is heard.

Replace fuse or reset circuit breaker.

Check for proper fuse amperage.

Check for low voltage conditions.

Disconnect any other electrical appliances from circuit or
operate air compressor on its own branch circuit.

Check chart on page #9 for proper gauge wire and cord length.

Motor will start automatically when air tank pressure drops
below “cut-in” pressure of motor/pressure switch.

Bleed the line by moving the switch to the “Off” position.

Contact Senco Customer Service.

Tighten pulley and or flywheel.

Add correct amount of oil. Check for bearing damage.

Remove cylinder head and inspect. Clean or replace.

STOP THE COMPRESSOR! Contact Senco Customer
Service.

Содержание PC1005

Страница 1: ...the safe use of this compressor are included in this manual PC 1005 Electric Air Compressor Questions Comments call SENCO S toll free Action line 1 888 222 8144 or e mail toolprof senco com Code 19773...

Страница 2: ...5 BREATHING 6 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 7 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 COMPRESSOR FEATURES 8 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 ELECTRICAL 10 OPERATION 11 PRE START CHECK...

Страница 3: ...ot avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potentially hazar...

Страница 4: ...electrical cords to lay in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the electrical cord to disconnect from the outlet Nev...

Страница 5: ...ble dust gases or other combustible materials If spraying flammable material locate the air compressor at least 20 feet away from the spray area An additional hose may be required Never place objects...

Страница 6: ...from the air compressor either directly or from a breathing device connected to the air compressor Operate air compressor only in a well ventilated area Follow all safety instructions provided with t...

Страница 7: ...restart at any time Do not operate without protective covers guards Replace damaged covers guards before using the air compressor Never allow children or adolescents to operate this air compressor St...

Страница 8: ...Reset 3 Air Intake Filter 4 Air Compressor Pump 5 Air tank drain valve 6 Tank Pressure Gauge 7 Outlet Pressure Gauge 8 Pressure Regulator 9 Oil Dipstick 10 Oil Drain 11 Discharge Line 12 115 Volt Elec...

Страница 9: ...obstructions The filter can be removed for cleaning by using warm soapy water Rinse the filter and air dry Replace filter when necessary 4 AIR COMPRESSOR PUMP To compress air the pistons move up and...

Страница 10: ...sary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire WARNING This pr...

Страница 11: ...less pressure and clockwise for more pressure 6 If you notice any unusual noise or vibration stop the air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the lever...

Страница 12: ...e Plug cord into grounded outlet Move switch to AUTO position Turn air compressor off wait until motor is cool then press motor thermal overload red button firmly until click is heard Replace fuse or...

Страница 13: ...city of the air compressor Either use a smaller tool or a larger air compressor REMEDY Remove clean or replace REMEDY Replace REMEDY Operate safety relief valve manually by pulling on ring If it still...

Страница 14: ...st pressure regulator knob to proper setting or replace Clean or replace Check for leaks and repair Replace with larger hose or connectors Check the accessory air requirement If it is higher than the...

Страница 15: ...uminium steel sleewer Valves Reed Single Head Aluminium Filter Canister Motor Pressure Switch Setting Cut out 125 PSI Cut in 95 PSI Controls Pressure switch Air tank Capacity 2 5 gallon Performance CF...

Страница 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...

Отзывы: