14
Slide mechanism ”sticks” or
returns slowly
Debris build-up in mechanism
Clean mechanism
Weak return spring
Replace or return to Senco
authorized service centre for repair
Bit sticking in collation material
Use Senco branded fasteners for
optimum performance
Always attempt to store screws
in cool, dry place before use.
Overheated collation can get soft
and cause a delay in feed system
return
Pushing force becomes excessive
Improper screw for application
Consider alternative fastener
CAM screw is loose or damaged
Tighten or replace CAM screw
Debris build-up on mechanism
Clean mechanism
Attachment will not fully
install/lock
The attachment is not fully insert-
ed and seated onto the tool
Verify that the attachment is fully
seated before attempting to lock
the collar
The clamp is not turned to the full
unlock position
Rotate the clamp to full unlock
position
Foreign object stuck inside
attachment
Make sure that no objects or parts
are jammed inside the connection
Components in connector may be
damaged
Replace connector or return to
Senco Authorized service centre
for repair
Attachment will not fully
uninstall/unlock
The clamp is not turned to the full
unlock position
Rotate the clamp to full unlock
position
The attachment is catching on the
front end of the tool
Avoid removing at any angle, pull
attachment straight off and away
from the tool to remove
When in full unlock position,
maneuver attachment up and
down to disengage grabbing
features from tool
Foreign object stuck inside
attachment
Be sure that no objects or parts
are jammed inside the connection
Components in connector may be
damaged
Replace connector or return to
Senco Authorized service centre
for repair