For Recoil start, firmly grasp the recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.
For electric start, turn and hold key in start switch to “start” position until generator starts.To prolong the life of starter
components, DO NOT hold key in “start” position for more than 15 seconds, and pause for at least 1 minute between
starting attempts.
NOTICE If battery is unavailable,use manual starting instructions.
NOTICE If engine is choking and running roughly,move choke lever to the OFF position and repeat starting instructions.
WARNING Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could
cause broken bones, fractures, bruises, or sprains resulting in serious injury.
When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
Never start or stop engine with electrical devices plugged in and turned on.
NOTICE If engine fails to start after 3 pulls, or if unit shut down during operation, make sure unit is on a level surface and check
for proper oil level in crankcase. This unit may be equipped with a low oil protection device. If so, oil must be checked at proper
level for engine to start and run.
WARNING Exhaust heat/ gases could ignite combustible, structures or damage fuel tank causing a fire, resulting in death,
serious injury and/or property damage. Contact with muffler area could cause burn resulting in serious injury.
DO NOT touch hot part and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (152 cm) of clearance on all sides of generator including overhead.
Contact the original equipment manufacturer, retailer , or dealer to obtain a spark arrester designed for the exhaust system
installed on this engine.
Replacement parts must be the same and installed in the same position as the original parts.
IMPORTANT Do not overload the generator. Also,do not overload individual panel receptacles. These outlets are protected
against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker
opens and electrical output to that receptacle is lost.
When engine starts, move choke lever to 1/2- CHOKE position till engine runs smoothly and then fully into ON position. If
engine flalters, move choke back to 1/2- CHOKE position
till engine running smoothly and then fully into ON position again.
Italia Star Com Due S.R.L.
www.italiastar.ro
004/021.433.03.27
85
Содержание SC-1250
Страница 5: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 3...
Страница 43: ...Senci Senci Group 1 Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 41...
Страница 44: ...2 1 5 e A Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 42...
Страница 45: ...5 Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 43...
Страница 48: ...4 30 4 3 4 2 10 85 Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 46...
Страница 49: ...Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 47...
Страница 50: ...5 5 1 OFF 15 1 Italia Star Com Due S R L www italiastar ro info italiastar ro 004 021 433 03 27 48...