9/13
SP-428 RBS setting & troubleshooting
•
How to set Remote base station?
1.
the connect cable need use twisted pair cable, one side with Pacific
connector ,next side with RJ11 connector
。
2.
Remote base station can direct plug to use, no require to register
with central unit. When plug cable to central unit, the LED will
flash cadence after
1~2
minute later is one second ON and one
second OFF
。
•
How to check/fix Remote base unit?
1.
When RBU plug cable with CU, for working case, the red color
LED will flash, If the red color LED No flash . Please check the
twisted pair jack and cable to see the connection well and the
DC power output at DC
48
V
。
2.
If NO DC 48V output ,please check the cable even broken or
DECT module NO DC 48V output
。
3.
If the cable have DC 48V output ,but remote bast station of red
color LED NO flash ,please send the RBU to SENAO repair
center
。