Sena Parani-MSP1000 Скачать руководство пользователя страница 6

Appendix 1. Connections 

43

 

A 1.1. Ethernet Pin outs...................................................................................................................43

 

A 1.2. Console and Serial port pin-outs...........................................................................................43

 

A 1.3. Ethernet Wiring Diagram.......................................................................................................44

 

Appendix 2. Parani-MSP1000 Configuration files 

45

 

A 2.1. ip.conf....................................................................................................................................45

 

Appendix 3. Well-known port numbers 

46

 

Appendix 4. Guide to the Bios menu program 

47

 

Appendix 5: Warranty 

48

 

A.5.1. GENERAL WARRANTY POLICY .........................................................................................48

 

A.5.2. LIMITATION OF LIABILITY...................................................................................................48

 

A.5.3. HARDWARE PRODUCT WARRANTY DETAILS .................................................................48

 

A.5.4. SOFTWARE PRODUCT WARRANTY DETAILS .................................................................49

 

A.5.5. THIRD-PARTY SOFTWARE PRODUCT WARRANTY DETAILS.........................................49

 

Содержание Parani-MSP1000

Страница 1: ...Parani MSP1000 For Wireless Multi Serial Communications based on Bluetooth Technology User Guide Version 0 0 1 2007 05 28...

Страница 2: ...otice to Users Proper back up systems and necessary safety devices should be utilized to protect against injury death or property damage due to system failure Such protection is the responsibility of...

Страница 3: ...3 Revision History Revision Date Name Description V0 0 1 2007 08 16 Hanjun Yeom Initial Draft...

Страница 4: ...guration 21 3 5 TCP service Configuration 22 4 Bluetooth Configuration 24 4 1 Overview 24 4 2 Device Configuration 24 4 2 1 Bluetooth friendly name 4 2 2 Inquiry scan 4 2 3 Page scan 4 2 4 Authenticat...

Страница 5: ...33 7 3 Bluetooth connection monitoring 33 8 System statistics 34 8 1 Network interfaces 34 8 2 IP 34 8 3 ICMP 35 8 4 TCP 37 8 5 UDP 38 9 CLI guide 39 9 1 Introduction 39 9 2 Flash partitions 39 9 3 Su...

Страница 6: ...0 Configuration files 45 A 2 1 ip conf 45 Appendix 3 Well known port numbers 46 Appendix 4 Guide to the Bios menu program 47 Appendix 5 Warranty 48 A 5 1 GENERAL WARRANTY POLICY 48 A 5 2 LIMITATION OF...

Страница 7: ...ransmitted to the Parani MSP1000 The dual Ethernet fail over feature may be also helpful to the users who want to apply this box in mission critical fail safe applications The Parani MSP1000 series is...

Страница 8: ...00m Point to multi point connectivity MSP1000A Up to 7 Bluetooth connections MSP1000B Up to 14 Bluetooth connections MSP1000C Up to 28 Bluetooth connections Network Protocols IPv4 ICMP ARP TCP HTTP Te...

Страница 9: ...iding the active WiFi channel from Bluetooth link However AFH does not provide a complete solution making WiFi and Bluetooth work together in harmony It is highly recommended for users to test their w...

Страница 10: ...trength Bluetooth of Bluetooth Connections Shows the number of Bluetooth sessions currently connected to the Parani MSP1000 Status Solid GREEN if system is running and ready to be used System Power So...

Страница 11: ...th0 blink to indicate incoming outgoing Ethernet packets Figure 2 2 Connecting a network cable to the MSP1000 2 4 Configurations The Parani MSP1000 provides several paths to set up the box to make it...

Страница 12: ...ect to the Parani MSP1000 using a conventional web browser such as Internet Explorer or Firefox Navigator Easy to use menu driven user interface provides full featured configuration functions for the...

Страница 13: ...1 Network configuration 2 System administration 3 System status log 4 CF card configuration 5 Monitoring 6 Save changes 7 Exit without saving 8 Exit and apply changes 9 Exit and reboot ESC Back ENTER...

Страница 14: ...er entering apply command on the menu 2 4 2 Configurations using Ethernet connection The IP address of the Parani MSP1000 must be known before users can access the box using the Remote console The def...

Страница 15: ...e 2 4 Login screen of the Parani MSP1000 web management Figure 2 5 The Parani MSP1000 Series web management screen Figure 2 5 shows the configuration homepage of the Parani MSP1000 Web management inte...

Страница 16: ...ges made will be lost and the previous values restored But the changes that are already saved or applied cannot be canceled 2 4 3 Configurations using Bluetooth wireless connection The Parani MSP1000...

Страница 17: ...nitially defaulted to STATIC mode with a static IP address of 192 168 161 5 Table 3 1 shows the configuration parameters for all three IP configurations Figure 3 1 shows the actual web based GUI to ch...

Страница 18: ...raphic location on the local network segment as defined by the subnet mask the Parani MSP1000 will establish a direct connection If the desired TCP IP host specified in the packet is not identified as...

Страница 19: ...Each time the device is reset the Parani MSP1000 broadcasts a DHCP request over the network The reply generated by the DHCP server contains the IP address as well as the subnet mask gateway address D...

Страница 20: ...supports the use of a remote message logging service SYSLOG service for the system and port data logging To use the remote SYSLOG service the user must specify the SYSLOG server s IP address and the...

Страница 21: ...Interface Apply IP filtering rule to the incoming packet of Parani MSP1000 This is configurable one of eth0 or pan0 z Option and IP address mask Input field to describe a specific range of host on the...

Страница 22: ...xcept 192 168 1 120 192 168 1 120 255 255 255 255 Invert 192 168 1 1 192 168 1 254 192 168 1 0 255 255 255 0 Normal 192 168 0 1 192 168 255 254 192 168 0 0 255 255 0 0 Normal 192 168 1 1 192 168 1 126...

Страница 23: ...s by the Parani MSP1000 These keep alive messages are sent to the remote host to confirm that the session is still open The default time value is 15 sec z TCP keep alive probes This represents how man...

Страница 24: ...onnection will be rejected z Pass key The pass key is also called as PIN code This pass key is used for incoming and outgoing connections both z Encryption When this is enabled the Parani MSP1000 appl...

Страница 25: ...ns neighborhood Bluetooth devices with this interval in seconds This value means the time required for the Parani MSP1000 to recognize a new device Note Too short interval may make the data rate slow...

Страница 26: ...able The frame buffer functionality is disabled The Parani MSP1000 sends the data received from SPP to remote hosts as soon as possible z Fixed size The Parani MSP1000 waits until the received data si...

Страница 27: ...When the operation mode is Initiate accept connection to from specific devices the local port number is configurable and when the operation mode is the other the base port number is configurable The P...

Страница 28: ...iguration Please refer to 4 3 2 1 Port configuration 4 3 3 2 SPP connections The current SPP connections are displayed 4 3 4 Operation mode Initiate Accept connection to from specific devices The Para...

Страница 29: ...ging the data z Log location The data is able to be logged to memory or CF memory when a CF memory is plugged The logged data is saved to a file of which name is portlogs the_BD_address log z Data str...

Страница 30: ...ay Every day AM 00 00 00 Every hour Every hour 0 minute 0 second 4 4 PAN DUN LAP Configuration 4 4 1 Private address 4 4 2 Personal Area Networking PAN 4 4 3 Dial Up Networking DUN 4 4 4 LAN Access ov...

Страница 31: ...31 5 CF card Configuration 5 1 When using a flash memory card...

Страница 32: ...3 Certificates 6 3 1 Changing certificate 6 3 2 Changing private key 6 3 3 Uploading a new Trusted CA certificate 6 3 4 Removing a Trusted CA certificate 6 4 Date and Time 6 5 Configuration management...

Страница 33: ...33 7 System status log 7 1 System status 7 2 System logging 7 2 1 System log location 7 2 2 System log buffer size 7 2 3 Lessen system log 7 3 Bluetooth connection monitoring...

Страница 34: ...ut datagrams discarded due to errors in their IP headers including bad checksums version number mismatch other format errors time to live exceeded errors discovered in processing their IP options etc...

Страница 35: ...discarded This counter includes any packets counted in Datagrams Forwarded that meet this no route criterion ReasmTimeout Specifies the amount of time allowed for all pieces of a fragmented datagram...

Страница 36: ...IP header InSrcQuenchs OutSrcQuenchs Specifies the number of source quench messages received or sent A source quench request is sent to a computer to request that it reduces its rate of packet transmi...

Страница 37: ...transmission time out RTO algorithm in use The Retransmission Algorithm can have one of the following values 0 CONSTANT Constant Time out 1 RSRE MIL STD 1778 Appendix B 2 VANJ Van Jacobson s Algorithm...

Страница 38: ...et flag set Figure 8 4 TCP statistics 8 5 UDP The UDP Statistics screen provides statistical information about packets connections using a UDP protocol Definitions and descriptions of each parameter a...

Страница 39: ...to the internal flash memory area of the Pro Series This will result in the changes being kept after the reboot sequence Invalid configuration changes can affect the Pro Series behavior At worst it m...

Страница 40: ...40 Telnet console 1 telnet Parani MSP1000_IP_address SSH console 1 ssh Parani MSP1000_IP_address...

Страница 41: ...icular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to corr...

Страница 42: ...11 2 Number of Frequency Channel 79 channels 11 3 Transmission Method FHSS Frequency Hopping Spread Spectrum 11 4 Modulation Method GFSK Gaussian filtered Frequency Shift Keying 11 5 Radio Output Powe...

Страница 43: ...ge 3 Rx White with green 4 NC Blue 5 NC White with blue 6 Rx Green 7 NC White with brown 8 NC Brown A 1 2 Console and Serial port pin outs The pin assignment of the PS110 PS410 PS810 DB9 connector is...

Страница 44: ...ion of each DIP switch as shown below But please note that the power of the Pro Series should be turned off before changing the serial communication type Figure A 3 Serial communication type and DIP s...

Страница 45: ...45 Appendix 2 Parani MSP1000 Configuration files A 2 1 ip conf...

Страница 46: ...ms executed by privileged users Table A 3 shows some of the well known port numbers For more details please visit the IANA website http www iana org assignments port numbers Table A 3 Well known port...

Страница 47: ...47 Appendix 4 Guide to the Bios menu program...

Страница 48: ...CIAL OR CONSEQUENTIAL DAMAGES WHETHER IN AN ACTION IN CONTRACT OR TORT INCLUDING NEGLIGENCE AND STRICT LIABILITY SUCH AS BUT NOT LIMITED TO LOSS OF ANTICIPATED PROFITS OR BENEFITS RESULTING FROM OR AR...

Страница 49: ...chemistry lack of maintenance A 5 4 SOFTWARE PRODUCT WARRANTY DETAILS WARRANTY PERIOD SENA warranties software Product for a period of one 1 year WARRANTY COVERAGE SENA warranty will be limited to pr...

Отзывы: