7
OPERATING INSTRUCTIONS
Power On/Off
●
Turn on the power by pressing the power
button for 2 seconds. Once on, the
scale will flash the voltage and then begin to auto-check and count down from 0-9
sequentially before entering the weighing mode
Note:
Anything on the scale before powering on will automatically be tared out.
Zeroing
●
The zero function is used only when the scale is empty and is not at gross zero due
to material build up (such as a chain or rope)
●
Pressing the
ZERO
key will reset your scale to 0
●
Depending on what your manual zero range parameter is set to, you can zero out
any number within your set selection, after that you will receive an error and will
need to tare out the weight
Unit Selection
●
To switch between measuring units (kg/lb) press the
2nd
key followed by the
Zero
key to switch between units
Tare Function
●
The Tare function is used when you only wish to see the current change in weight,
not the entire amount of weight that is on the scale
●
When the scale is in gross mode pressing the
TARE
key will Tare the current
weight on the scale and enter the net mode
●
For example if you are using a chain add the chain to the scale, press tare and the
display will show the tare symbol
and reset back to 0
●
Add your product to the scale to weigh without the weight of the chain
●
To exit Tare mode press the TARE key again to enter gross mode and you will see
the total weight of the container and the product
Note
: If you remove the chain the scale will show the minus weight of the chain
To use a pre-set tare weight
●
Press
2nd
key, then press the
TARE
key; the display should now show [00000]
●
Using the arrow keys, input the tare weight value
●
Press
Hold
key to confirm and enter net weighing mode