8
Hold
To use the hold feature press the SET and ZERO keys at the same time. Press both again
to release the hold.
There are 4 different hold functions you can choose from in the C11 parameter
1. Peak Hold:
Grabs the highest weight
(for materials testing, ie. tension and pulling
force)
● Press the HOLD key then add weight to the scale
● The indicator will show the highest weight it recorded and hold it on the screen until
a higher weight is placed on the scale
2. Manual Hold:
Grabs the current weight and holds it so it will not change/fluctuate
● While weighing, press HOLD and the indicator will hold the current weight on the
screen until HOLD is pressed again
3. Auto Hold:
If the weight on the scale is above 20d (20 x division) and is stable,
the indicator will hold that weight on the screen for 3 seconds then go back to general
weighing
● Pressing the hold key is unnecessary, holding is done automatically when the scale
is stable
4. Average Hold:
Used for animal weighing, the indicator will display the average
weight sampled from 3 seconds
● Add livestock to scale and press HOLD
● Indicator screen will show “
LOC
” for 3 seconds, then display the average weight
from those 3 seconds
● Press HOLD again to exit holding mode
● If your pallet jack has a printer and the weight on the scale is stable press the SET key
for 1 second to print the current weight
Note: In tare mode the printer can not print if negative weight is shown
Print Out Format:
NO.
003
(S/N)
net
6.00kg
(Net weight)
tare
2.88kg
(Tare weight)
gross
8.88kg
(Gross weight)