![SellEton Scales OPF-C Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/selleton-scales/opf-c/opf-c_user-manual_1237074011.webp)
9
To Calibrate with 3 weights
You will need 3 weights 1/3, 2/3 and 3/3 of the max capacity.
• The left screen will read “
LIN
” and the right should read “
oN
”
(Press the [Zero] key to switch Lin to “
oN
” if it is "
off
”)
• Then press [Total] to enter segment calibration
• The left screen will read “
LINE 1
” and the right will flash “
0
”
• Confirm there is no weight on the pan before entering the weight
• Enter the value (in kg) of the first weight you will be using to calibrate
the scale (1/3rds of the capacity is preferred)
• Then set the calibration weight on the scale and press [M+] to confirm
• The left screen will read “
LINE 2
” and the right will flash “
0
”
• Enter the value (in kg) of the second weight you will be using to
calibrate the scale (2/3rds of the capacity is preferred)
• Then set the calibration weight on the scale and press [M+] to confirm
• The left screen will read “
LINE 3
” and the right will flash the max capacity
• You must use the weight shown on the screen (max capacity) to finish
calibration
• Once the weight is on the scale, press [M+] to confirm
• The display will flash “
PASS
” when calibration is done
• Press [UNIT WEIGHT] to go back to the weighing mode
• Calibration is complete