INSTALLING THE SMARTBOX MINI 

Before installation, check that the product is complete and has not suffered any damage 
during transport. 

ASSEMBLY, START-UP and MAINTENANCE are to be carried out by a specialised 
company in terms of water law.

 

For the system to function as intended it must be installed professionally in compliance with 
the technical instructions applicable to the planning, construction and operation of the entire 
system. 
These regulations also include the accident prevention regulations of the employers’ liability 
insurance associations, the VDE regulations, and the installation and operating instructions.

Installation instructions 

The display unit has a wall installation housing and is operated with the top of the housing 
closed. Installation and start-up by a specialised installer is carried out with the display unit 
open. 

Installation of the digital display unit 

1. Loosen the screw on the bottom of the digital display unit and remove the top of the
housing. 
2. Place the digital display unit on a suitable position on a smooth, vertical wall and pierce
the pre-cut holes on the inside back wall of the housing. Mark the points for installation. 

NOTICE 
Do not damage electronic components. 

Use a suitable tool to pierce the openings.

 

3. Place the digital display unit on the marks and fix it in place using the supplied anchors

and 

screws.

4. Close the top of the housing and tighten the screw on the bottom of the digital display unit.

TROUBLESHOOTING 

Fault cause 

Action 

Battery warning Battery _ _% 
when remaining capacity is low 

«

 Constant check 

No display 
Batteries empty 

«

 Replace batteries 

Error code 

Meaning 

Error 0001 

No contact with FSA-E 

Check the connection between the magnetic sensor 
and the magnetic encoder in the connection plug on 
the FSA-E 

Error 0002 

Connection cable on the digital display unit not connected 

Connect the cable 

22/72

Содержание Smartbox MINI

Страница 1: ...tal display unit CONTENTS ABOUT THESE INSTRUCTIONS 14 SAFETY ADVICE 14 ADDITIONAL SAFETY ADVICE 14 PRODUCT RELATED SAFETY ADVICE 15 GENERALLY 1 DESIGN 1 INTENDED USE 1 FUNCTION DESCRIPTION 1 CONNECTIONS START UP PROGRAMMING 22 INSTALLING THE SMARTBOX MINI 2 TROUBLESHOOTING 2 REPAIRS 2 MAINTENANCE 2 SHUT DOWN 2 DISPOSAL 2 WARRANTY 2 TECHNICAL CHANGES 2 TECHNICAL DATA 2 13 72 ...

Страница 2: ...elines NOTE Observe the installation and operating instructions for FSA E level gauge part no 15 276 50 SAFETY ADVICE DANGER describes a personal hazard with a high degree of risk May result in death or serious injury WARNING describes a personal hazard with a medium degree of risk May result in death or serious injury CAUTION describes a personal hazard with a low degree of risk May result in min...

Страница 3: ...he measurement data is output in a 16 character single row LCD display on the digital display unit The scale of the FSA E which is mounted directly on the tank also shows the level in the tank continuously in centimetres The FSA E 0 160 cm is suitable for all unpressurised tanks to a level of 150 cm for levels up to 240 cm use the FSA E 0 250 cm NOTE The SmartBox MINI is rated as Protection Class ...

Страница 4: ... x Not suitable for outdoor use FUNCTION DESCRIPTION The content of the tank is determined by measuring the level on the basis of the float principle With an electronic interface the measurement from the FSA E is sent via a connection cable to the SmartBox MINI digital display unit where it is converted into the set output value and shown on the display Installation example standard installation o...

Страница 5: ... Assemble the cable relief x Position the clip on ferrite core near the housing x Insert the batteries in the battery compartment of the digital display unit NOTICE Malfunction if cable is touched when live Permanent damage to the digital display unit cannot be ruled out Insert the batteries only after you have connected the cable NOTICE Malfunction as a result of incorrect wiring The proper funct...

Страница 6: ...it board Activate the display on the sensor bar The parameters are adjusted with three small push buttons MINUS ENTER PLUS SW6 SW4 SW5 These are located on the circuit board above the terminal block Terminal assignment from left to right 1 ws White 2 bn Brown 3 gn Green 4 gb Yellow 5 gr Grey Setting a parameter Press Enter to open setup mode Select the desired setting parameter via PLUS Press Ente...

Страница 7: ...shape Disp lay Type Litres Only when the FSA E is ready to Set Null 250cm FSA E max H 0cm to 150cm or 240cm max V 0L to 999999L Linear On Touch Height 160cm FSA E Cylinder Perma nent Percent Ball Exit Oval Click to confirm the selected values Æ OK Convex Concave At maximum height and maximum volume the values are set with or Cylinder 50000L Steel Tank 19 72 ...

Страница 8: ...ay in litres Percent Display volume in Height Display level in cm Set Null Zero offset adjustment between the digital display unit and the FSA E Adjustment with Set Null Sensor Type Enter the measuring range 250 cm FSA E Select a setting and confirm with Enter Ok is displayed 0 250 160 cm FSA E 0 160 maximum Height Enter the maximum internal height of the tank height without dome 250 cm FSA E Ente...

Страница 9: ...nvex shape alternative to linear Concave plastic battery tank concave slightly concave shape alternative to linear Cylinder 50000 L cylindrical largH RXWGRRU WDQN ޓ Pñ ޓ WR 100000 L Steel Tank Sheet steel tank or tank battery Straight side walls with semicircular dome at top and bottom Display Type Set the display OnTouch Select a setting and confirm with Enter Ok is displayed Value is displayed f...

Страница 10: ...ut with the display unit open Installation of the digital display unit 1 Loosen the screw on the bottom of the digital display unit and remove the top of the housing 2 Place the digital display unit on a suitable position on a smooth vertical wall and pierce the pre cut holes on the inside back wall of the housing Mark the points for installation NOTICE Do not damage electronic components Use a su...

Страница 11: ...ice out of service DISPOSAL To protect the environment our products may not be disposed of along with household waste The product must be disposed of via a local collection station or a recycling station Discharged batteries should be deposited at collection stations or in shops with collection facilities Stored data is not lost when you replace the battery WARRANTY We guarantee that the product w...

Страница 12: ...m Measuring range FSA E0 250 cm Level 0 to 240 cm Ambient temperature 0 C to 50 C Housing material ABS PC Type of protection IP30 acc to EN 60529 Notes for required tank data Menu step Entry function Entry value Sensor Type 250 cm FSA E R R 160 cm FSA E R R maximum Height 9DOXH 0D FP _ _ _ cm 9DOXH 0D FP _ _ _ cm maximum Volume 0D 9 _ _ _ _ _ _L Tank shape Linear R R Cylinder to 50 m R R Ball R R ...

Отзывы: