background image

(In Toronto Area only: 1-905-3061093)

For Parts, Service, Warranty or other Assistance, 
please call

 

1-800-442-1902 (In Canada: 1-800-387-0369)

NOTE TO INSTALLER: Please give this manual to the customer after installation.

(In Toronto Area only: 1-905-3061093)

SELECTRONIC

Proximity Integrated Faucet

with Optional Above-Deck Mixing

7055.105

7055.115
7056.105

7056.115

7055.205

7055.215
7056.205

7056.215

®

 Platform with Universal Sensor

®

To learn more about American Standard Faucets visit our website at: 

www.americanstandard-us.com

or U.S. customer's e-mail us at: 

[email protected]

Installation Instr

uctions

In

s

ta

ll

a

ti

o

n

 I

n

s

tr

u

c

ti

o

n

s

M 9 6 5 2 5 5   R E V.  1. 6

   

Flexible Selectronic

   

Easy installation. All electronics in the spout; nothing below deck.

   

User adjustable above-deck mixing uses ceramic disc
valve for dependability & long life

   

Mixing handle can be removed for one time temperature
setting during installation

   

Available in DC (Battery) & AC versions

Certified to comply with ASME A112.18.1M

© 2012 American Standard

Product No.'s & Options

Specifications

How to Install

Maintenance

FAQ,s

Replacement Parts

1

2

2-3

3-7

7-8

8

Содержание 7055.105

Страница 1: ...ur website at www americanstandard us com or U S customer s e mail us at faucetsupport americanstandard com I n s t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s M965255 REV 1 6 Flexible Selectronic Easy installation All electronics in the spout nothing below deck User adjustable above deck mixing uses ceramic disc valve for dependability long life Mixing ha...

Страница 2: ...support americanstandard com I n s t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s Product No s Options Specifications How to Install Maintenance FAQ s Replacement Parts 1 2 2 3 3 7 7 8 8 M965255 REV 1 6 Flexible Selectronic Easy installation All electronics in the spout nothing below deck User adjustable above deck mixing uses ceramic disc valve for dependa...

Страница 3: ...V 50 60 Hz IMPORTANT Do not use putty when installing faucet without escutcheon 10 MOUNTING SURFACE OPTIONAL TIGHTEN SPIN NUTS 1 Make sure O RING SEAL 9 is installed 2 Installation with ESCUTCHEON 1 optional Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE 1 Only if mounting surface is uneven 3 Insert supply HOSES 2 SHANK 3 and POWER CORD 10 if equipped through hole in ESCUTCHEO...

Страница 4: ...RONIC Thermostatic Mixing Valve Certified to comply with ASME A112 18 1M 2005 American Standard M968808 To learn more about American Standard Faucets visit our website at www us amstd com or U S customer s e mail us at faucetsupport amstd com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 NOTE TO INSTALLER Please give this manual to the customer ...

Страница 5: ...in 25 4 50 8mm in front of the sensor Fig 4 4 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set 6 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE...

Страница 6: ...L AND CHANGE BATTERY Fig 5 3 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Disconnect both WIRE CONNECTIONS Fig 6 3 Untighten SENSOR SCREW 1 with a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET BODY 3 Remove SENSOR 2a from ...

Страница 7: ... FAUCET COVER SCREW 4 and tighten See Fig 2 in this section HOWTO CLEAN FILTER SCREEN ON SOLENOIDVALVE Fig 9 10 5 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Pull out LIMITER STOP 1 from the VALVE STEM 2 Unthread COLLAR NUT 3 fro...

Страница 8: ...ing a wet cloth and dry using a soft cloth Do not scratch the sensor when cleaning Avoid using anything that may scratch the spout surface Never use polishing power detergent or a nylon scrub brush They will damage the surface of the spout or Sensor 8 M965255 REV 1 6 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at...

Страница 9: ...GPM AERATOR PRODUCT NUMBERS M900541 0020A FAUCET COVER FOR MIXING VALVE M900540 0020A FAUCET COVER LESS MIXING A912790 0070A VALVE STEM O RINGS M964188 0070A COLLAR NUT TEMPERATURE LIMITER STOP 705P400 ESCUTCHEON M964333 0070A HOSE ADAPTER M962146 0070A MOUNTING KIT M964187 0020A LEVER ASSEMBLY M950317 0070A AC POWER SUPPLY SELECTRONIC Proximity Integrated Faucet with Above Deck Mixing 7055 105 70...

Отзывы: