FAQ'S
Q:
How will I know if battery needs to be replaced?
A:
Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.
Q:
Why has the flow rate of the faucet reduced significantly?
A:
Check and clean aerator and strainer.
Q:
There is no flow out of faucet when I'm in the sensor range?
A:
Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1 800-442-1902.
Q:
What is the normal operating pressure range?
A:
Faucet will operate with supply pressures ranging from 20-80 psi.
7
CAUTION
GENERAL CLEANING; Fig. 14
1.
For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2.
For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface.
Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
8
M965255 REV. 1.6
1.
Remove the FAUCET COVER
(1)
by unthreading the
LEVER SCREW
(2)
and pulling off the LEVER
HANDLE
(3)
. Unthread the FAUCET COVER SCREW
(4)
at the back of the FAUCET. Pull FAUCET COVER
(1)
up and off. See
Fig. 2
in this section.
2.
Replace LEVER HANDLE and rotate
counter-clockwise to its stop position (100% cold).
Remove HANDLE.
3.
Pull out LIMITER STOP
(1)
from the VALVE STEM
(2)
.
4.
Rotate LIMITER STOP
(1)
180 degrees and insert
back onto VALVE STEM
(2)
.
5.
Replace FAUCET COVER
(1)
and LEVER HANDLE
(3)
. Install LEVER HANDLE SCREW
(2)
, FAUCET
COVER SCREW
(4)
and tighten. See
Fig. 2
in this
section.
CHANGE HOT LIMIT SETTING
FROM 95% TO 85%; Fig. 13
7
3
9
8
1
2
ROTATE 180
˚
SLOT
SLOT
Fig. 13