SE10 Manual
9
Selectronic Australia
Operation
Six LEDs are provided on the front panel to indicate a number of parameters,
and allow adjustment of some of these parameters.
LED (5) and (6) tells you what LED (1) – (4) is displaying as indicated on
the front panel of the SE10. Pressing Mode Button (7) will change the
information being displayed.
STATUS indicators LED (5) (green) flashing
When power is first applied LED (1) and (5) should flash.
When LED (5) (green) is flashing, this indicates the LED (1) – (4) is
showing the inverters STATSU, as per written notation to the right of the
LEDs. In this mode there are no adjustments to be made.
LED (1) Flashing
indicated the SE10 is in Auto Start mode, this indicates
that no power is being drawn from the inverter so it has gone to SLEEP to
save power. If no power is used within 12 minutes, the LED (1) will flash at
a slower rate therefore saving more power.
LED (1) Stays ON
, the inverter has been commanded to provide power to
the load (e.g. a light switch has been turned on) so it has gone from SLEEP
mode to ON. Once the load has been removed (e.g. the light switch is turned
off) the inverter will wait 10 seconds and return to SLEEP mode.
It is good practice to have your SE10 in SLEEP mode as often as
possible. When the SE10 is in SLEEP mode it uses 0.045 amps
from the battery, when the inverter is in the ON mode it uses at
least 0.3 amps from the battery.
The amount of power required to go from SLEEP to ON is adjustable and is
described on page 11.