background image

LD350-12 Volt Owners Manual 

 . 

 
 
 
 
 
 
 
 

LD350-12 Operating Manual 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

Serial No  _____________________________  

Purchase Date  ______________ 

Note - Your 2 Year Warranty can only be valid once your warranty card is completed and returned to Selectronic Australia 

 

 

USTRALIA

ELECTRONIC

 

 

A

 

S

 

Contents 

Page No. 

Introduction   

1

Warranty Card 

Installation   

1

Batteries and Connections 

Getting Started Quickly 

Parts Identification 

Operation   

7

STATUS Indicators 

Demand Start Setting 

Low Voltage Shutdown Setting 

10 

Maintenance 

 

11

Inverter 

 

11

Batteries 

 

11

Handy Hint 

12 

Radio Frequency Interference 

13 

Fault Finding 

14 

Product Warranty Conditions 

15 

Specifications 

 

16

Selectronic Service Network 

 

 

Back Cover

 
 
 
 

Legend for Symbols 

 

 

 

Warnings and 

electrician’s notes 

 

Hints and Pointers 

 

Examples 

Содержание LD350-12

Страница 1: ...o Introduction 1 Warranty Card 1 Installation 1 Batteries and Connections 4 Getting Started Quickly 6 Parts Identification 6 Operation 7 STATUS Indicators 7 Demand Start Setting 9 Low Voltage Shutdown Setting 10 Maintenance 11 Inverter 11 Batteries 11 Handy Hint 12 Radio Frequency Interference 13 Fault Finding 14 Product Warranty Conditions 15 Specifications 16 Selectronic Service Network Back Cov...

Страница 2: ... card please feel free to drop us a line Yes constructive criticism will also be welcome Installation A system fuse of at least 40 Amps should be placed before the battery An HRC motor start type is recommended See your system designer for details 200mm 200mm 200mm LD350 12 Inverter Front 200mm LD350 12 Inverter Warning As a matter of safety Selectronic strongly recommend that all fixed installati...

Страница 3: ... be stored in a battery this figure will generally be stated at a particular hour rate This is how a deep cycle or storage battery would normally be rated Start Battery By incorporating an auxiliary battery in the manner above the starting battery should remain charged for vehicle starting see your auto electrician The LD350 12 has sufficient battery cable length to allow it to sit underneath the ...

Страница 4: ...ting of a battery will also be reduced if the drain current is greater than the rated discharge current See your battery specifications for full details If you want to get powered up quickly here are the 11 simple steps 1 Familiarise yourself with the details in the first 6 pages on this manual 2 Unpack the LD350 12 from the packaging 3 Check unit for any damage that may have resulted during trans...

Страница 5: ...rom the inverter so it has gone to SLEEP to save power If no power is used within 12 minutes the LED 1 will flash at a slower rate therefore saving more power LED 3 will continue to flash until the battery volts have risen sufficiently In this case charge the battery by starting the vehicle or using a battery charger The low voltage point that the inverter will cut out is adjustable to suit your p...

Страница 6: ...econds Hold the Mode button 7 down until LED 5 is FLASHING approximately 2 seconds indicating you are ready to adjust this setting Now press the Mode button 7 until the desired value is sought LEDs 1 4 will return to Status after 20 seconds Low Volts Cut out LED 1 LED 2 LED 3 LED 4 10 0 Volts 10 1 Volts 10 2 Volts 10 3 Volts 10 4 Volts Slow Flash Medium Flash Fast Flash Fastest Flash ON ON ON ON O...

Страница 7: ...he inverter s operation by flashing when the inverter is in SLEEP mode and remaining ON when the inverter is brought ON by a load Batteries 1 Every week carry out a thorough visual inspection of all battery wiring taking particular note of the condition of inter connections between cells This maintenance should be carried out in conjunction with the battery manufacturers recommended maintenance Sa...

Страница 8: ...r be housed at least 15 metres from the home Check again to make sure that there are no appliances left ON the sequentially switch off appliances at the wall and by watching your night light as described in Handy Hint check to see if the LD350 12 returns to pulsing SLEEP mode after a 10 second delay Once you have found the offending appliance increase the sensitivity of the Demand Start see page 1...

Страница 9: ...e inverter Outside Australia New Zealand Product purchased for use outside Australia New Zealand must be returned to Selectronic Australia s Service Centre to enable warranty claims to be processed Freight cost to be borne by the customer No charge will be made for the product return LD350 12 Manual Selectronic Australia 16 Inverter Type Microprocessor control circuit with PWM full bridge power st...

Страница 10: ...Memory Retention Operating Temperature Range Transformer Type Cooling Method Power Point Chassis Material Chassis Coating Size Full Electronic Protection 4 12 volt input 50Hz 0 01 90 4 Permanent 0º C to 40º C Toroidal Controlled fan forced 10 Amp Single Pole Zinc Coated Steel Powder Coated 230W x 130H x 260mm D LD350 12 Manual Selectronic Australia 17 ...

Страница 11: ... NSW 2171 NSW 2480 Australia Australia Ph 02 9606 0279 Ph 02 6689 1430 Fax 02 6689 1109 Reid Technology Ltd 3 5 Auburn Street Solar Inverter Services Takapuna 13 Thirteenth Ave North Shore City Sawtell Auckland NZ NSW Ph 9 489 8100 2452 Fax 9 489 8585 Ph 02 66581733 ps reidtechnology co nz Part No ST M LD351 REV 2 24 02 04 SELECTRONIC AUSTRALIA 25 Holloway Drive Bayswater Victoria 3153 Australia P...

Отзывы: