Performer Operation Manual
8
Hour Meter
This shows the total elapsed time the Performer Series Followspot has been switched on. The Hour Meter is
intended to serve as a guide for the elapsed hour use of the lamp, to enable the replacement of the lamp
when the recommended lamp life hours have elapsed (750 hours)
When switched on for the first time, the Hour Meter will display an elapsed time of one hour. Before leaving
the factory, the Performer Followspot is switched on for one hour as part of the testing cycle.
When the lamp is replaced, it is good practice to record the setting on the hour meter in a log book. This
enables the user to know when subsequent lamps should be replaced.
On / Off Switch
Used to turn the Performer Series Followspot on and off. The circuit breaker for the Performer Series 2
Followspot is an integral part of the switch.
Manufacturer: E T A
Rating: 16A
Part Number: 3120-F72R-N7M1-A30QB4
Selecon Order Code: FSELE006
Earth Continuity Indicator
This should be illuminated green when the Performer Series 2 Followspot is switched on.
Important Note: If the indicator is not illuminated, do not touch the Followspot.
Switch the Followspot off at the mains power supply, and contact a qualified
service agent.
Peak / Flat Lamp Adjustment Control Knob
This is used to alter the field of the beam between Peak and Flat. The peak beam gives a central hot spot
falling off evenly to the beam edges. Flat adjustment provides a visually even light beam.
Earth Test Point
Use this point to place the electrode when testing the earth connection on the followspot.
Important note: The followspot contains electronics. Do not perform a “MEGA”
style test. Damage to the unit may result and will void your warranty.
Version 2: January 2009 © 2009 Selecon New Zealand Limited. All Rights Reserved