Selecon Rama Fresnel Series Скачать руководство пользователя страница 3

North America 

Version 4: September 2010  

 © Selecon  

 All Rights Reserved 

YOKE PIVOT ADJUSTMENT 

The  yoke  on  the  Rama  range  can  be  positioned  anywhere  in  the  channel  that  runs  the  length  of  the  fixture.  This  is 
useful to achieve the best balance if using a color changer or other accessory mounted on the front of the fixture, or to 
fit the fixture in space restricted positions. 

The  yoke balance point is factory set on the lamp house for normal applications.  To move the  yoke, loosen the  M8 
bolt at the bottom pivot point of the yoke on the right side of the fixture.  Release the tilt locking clamp on the left side 
of the fixture, and slide the yoke to the required position. Check the yoke is evenly positioned on each side and tighten 
the  M8  bolt, and  the tilt  locking clamp. To return the  yoke to its  original  balance  point,  align the  yoke to the balance 
point marked on the focus reference scale. 

PAN AND TILT ADJUSTMENT  

Rama 

6” Fresnel and PC, Rama 7” Fresnel and PC 

To  pan  your  fixture,  loosen  the  yoke  nut  and  bolt  holding  the  hookclamp  onto  the  yoke  and  adjust  the  yoke  as 
required, then retighten the yoke nut and bolt. 

The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt  friction can 
be  adjusted  by  loosening  or  tightening  up  the  nylock  nut.  To  tilt  your  fixture,  turn  the  tilt  lock knob  clockwise, tilt  the 
fixture to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on 
the locking clamp disc to prefocus the fixture if desired. 

NOTE: the handles and integrated safety bond on the Rama range can reach high temperatures depending on 
the position or orientation of the fixture: gloves should always be worn when focusing these fixtures. 

Rama 

6” FFT Fresnel and PC, Rama 7” FFT HP Fresnel and PC 

The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment. To pan your luminaire turn 
the pan locker a ¼ turn clockwise and adjust the yoke as required, then turn the pan locker a ¼ turn anticlockwise to 
set the position. A pan angle reference scale is provided on the FFT pan assembly to prefocus the fixture if desired. 

The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt friction can 
be  adjusted  by  loosening  or  tightening  up  the  nylock  nut.  To  tilt  your  fixture,  turn  the  tilt  lock knob  clockwise, tilt  the 
fixture to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on 
the locking clamp disc to prefocus the fixture if desired. 

 ACCESSORIES 

Suspension Hook Clamp (Order Code: 20HC)

Lens Safety Mesh (Order Code: 20SM6)

Color Frame 

– the fixture is supplied with a color frame 7 3/8” x 7 ½”. Additional color frames are available (Order

Code: 20CFRA12).

Barndoor (Order Code: 20BDSF12)

EARTH TEST POINT 

There is an earth test point located on the rear housing of the Rama. The earth test point is the silver machine screw 
located on the right side of the rear housing, and is indicated by an earth symbol. To test the earth of the Rama, place 
the test probe on the silver machine screw, and perform the earth test.  

CLEANING 

Open the down-swinging door, and clean the lens and/or reflector with a soft lint-free cloth. 

This is the  only  maintenance  task, which  can be  safely  carried  out  by  non-approved  personnel. 
Refer below 

– Safety & Maintenance note. 

SAFETY & MAINTENANCE 

 Selecon  has  manufactured  this  fixture  in  accordance  with  recognised  best 

practices  to recommended international safety standards.  It is  your responsibility to maintain this fixture in good and 
safe working condition. 

Содержание Rama Fresnel Series

Страница 1: ... THE FIXTURE FROM THE POWER SUPPLY Be aware also that the lamp fixture or integrated safety bond may still be hot so exercise the necessary caution to avoid burns Please note also that these fixtures are not suitable for mounting on a normally flammable surface The Selecon Rama Fresnel and PC range comprises four models the High Performance 7 Fresnel High Performance 7 PC 6 Fresnel and 6 PC Seleco...

Страница 2: ...r of the lamphouse and loop the safety chain around the bar fastening the clip onto the safety chain Be careful to allow sufficient slack to enable the fixture to be focussed freely To replace the safety chain remove the rear lamphouse molding slide out the safety chain locking clamp and pull out the safety chain taking care to retain the safety chain loop bar Reverse the process with a new safety...

Страница 3: ...d always be worn when focusing these fixtures Rama 6 FFT Fresnel and PC Rama 7 FFT HP Fresnel and PC The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment To pan your luminaire turn the pan locker a turn clockwise and adjust the yoke as required then turn the pan locker a turn anticlockwise to set the position A pan angle reference scale is provided on the FFT pan ...

Страница 4: ...nty claim Selecon will provide or arrange for service repair or replacement as Selecon shall determine in its sole discretion Selecon shall bear the cost of such service repair or replacement However the owner shall bear the cost of freight and insurance on the fixture both ways If Selecon does not wish to service repair or replace the defective fixture it shall refund the purchase price Selecon s...

Отзывы: