North America
Version 4: September 2010
© Selecon
All Rights Reserved
YOKE PIVOT ADJUSTMENT
The yoke on the Rama range can be positioned anywhere in the channel that runs the length of the fixture. This is
useful to achieve the best balance if using a color changer or other accessory mounted on the front of the fixture, or to
fit the fixture in space restricted positions.
The yoke balance point is factory set on the lamp house for normal applications. To move the yoke, loosen the M8
bolt at the bottom pivot point of the yoke on the right side of the fixture. Release the tilt locking clamp on the left side
of the fixture, and slide the yoke to the required position. Check the yoke is evenly positioned on each side and tighten
the M8 bolt, and the tilt locking clamp. To return the yoke to its original balance point, align the yoke to the balance
point marked on the focus reference scale.
PAN AND TILT ADJUSTMENT
Rama
6” Fresnel and PC, Rama 7” Fresnel and PC
To pan your fixture, loosen the yoke nut and bolt holding the hookclamp onto the yoke and adjust the yoke as
required, then retighten the yoke nut and bolt.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt friction can
be adjusted by loosening or tightening up the nylock nut. To tilt your fixture, turn the tilt lock knob clockwise, tilt the
fixture to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on
the locking clamp disc to prefocus the fixture if desired.
NOTE: the handles and integrated safety bond on the Rama range can reach high temperatures depending on
the position or orientation of the fixture: gloves should always be worn when focusing these fixtures.
Rama
6” FFT Fresnel and PC, Rama 7” FFT HP Fresnel and PC
The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment. To pan your luminaire turn
the pan locker a ¼ turn clockwise and adjust the yoke as required, then turn the pan locker a ¼ turn anticlockwise to
set the position. A pan angle reference scale is provided on the FFT pan assembly to prefocus the fixture if desired.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt friction can
be adjusted by loosening or tightening up the nylock nut. To tilt your fixture, turn the tilt lock knob clockwise, tilt the
fixture to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on
the locking clamp disc to prefocus the fixture if desired.
ACCESSORIES
Suspension Hook Clamp (Order Code: 20HC)
Lens Safety Mesh (Order Code: 20SM6)
Color Frame
– the fixture is supplied with a color frame 7 3/8” x 7 ½”. Additional color frames are available (Order
Code: 20CFRA12).
Barndoor (Order Code: 20BDSF12)
EARTH TEST POINT
There is an earth test point located on the rear housing of the Rama. The earth test point is the silver machine screw
located on the right side of the rear housing, and is indicated by an earth symbol. To test the earth of the Rama, place
the test probe on the silver machine screw, and perform the earth test.
CLEANING
Open the down-swinging door, and clean the lens and/or reflector with a soft lint-free cloth.
This is the only maintenance task, which can be safely carried out by non-approved personnel.
Refer below
– Safety & Maintenance note.
SAFETY & MAINTENANCE
Selecon has manufactured this fixture in accordance with recognised best
practices to recommended international safety standards. It is your responsibility to maintain this fixture in good and
safe working condition.