Selecon Pacific Dowser Скачать руководство пользователя страница 7

Pacific Dowser Manual

7

7

Version 5: January 2005            

©

 2004 Selecon New Zealand Limited All Rights Reserved

When using a 5.5-13

0

 lens tube, the assembled Pacific should be hung from the 5.5-13

0

 lens tube

yoke. Rotate the yoke on the dowser so that it is in a similar position to the one shown in the diagram
above. This keeps the yoke out of the way and helps to counter balance the Pacific.  
Slide the lamp house sideways into place into the lamp house slot and screw the lens tube locking
knob into the lamp house, securing the lamp house and dowser together. Next, insert the lens tube
into the lens tube holder of the dowser and screw the lens tube locking knob into the dowser’s lens
tube locking knob fixing point.

Powercon Connector

The dowser comes supplied with a Powercon connector for the mains power supply.
This connector can be plugged into the Powercon socket that is fitted on the MSR ballast power
supply. If you wish to power the dowser separately from the MSR ballast power supply, the connector
will need to be changed by a suitably qualified technician.

The Cable Conductor colour codes are as follows:

Brown

- Phase, Live 

Blue - 

Neutral

Green/Yellow

- Earth

Dowser Control Panel

It is possible to configure the
dowser for different types of
operation. The dowser has the
following user adjustable
features:

1.  DMX Address for remote

operation

2.  Local control for stand alone

operation

3.  Display on/low/off

DMX Operation

The dowser accepts any DMX
signal that adheres to DMX-512 USITT (1990). It is assumed that the user is familiar with this protocol.
Information on the standard can be obtained from USITT (

www.usitt.org)

. Please refer to the

recommended DMX layout diagram later in this manual.

DMX Address Setting 

The DMX address setting is adjusted on the dowser control panel. To change the DMX address
setting, press and hold the [ENTER] button until the LED display goes blank. Three digits will flash on
the LED display showing the current DMX address setting. Press the [+] or [-] buttons to change the
DMX address. To save the setting, press and hold the [ENTER] button for 2 seconds. 

Please note

that the local level must be set to {00} to enable DMX control.

Local Level Control

It is possible to control the dowser in stand alone mode if there is no remote control. The user can set
a default level for the dowser. The dowser will move to this level on start up. To adjust the local level,
press and hold the [ENTER] button until the LED display goes blank. Three digits will flash on the LED
Display showing the current DMX Address Setting. Press the [ENTER] button. Two digits will flash on
the LED display showing the current local level setting. Press the [+] or [-] buttons to change the local

Содержание Pacific Dowser

Страница 1: ...A SELECON PACIFIC LUMINAIRE ACCESSORY WE HAVE DESIGNED THIS LUMINAIRE ACCESSORY TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR...

Страница 2: ...s no liability for direct indirect incidental special or consequential damages resulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manu...

Страница 3: ...rmance Warning 5 Assembling the Dowser onto a Pacific 6 Powercon Connector 7 Dowser Control Panel 7 DMX Operation 7 DMX Address Setting 7 Local Level Control 7 Display Setting 8 Recommended DMX Distri...

Страница 4: ...le for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The Pacific range can be operated only through a range of angles 90 either side...

Страница 5: ...nd a secure independent anchor point Prolonged use of the dowser with the arms closed and the light source on will result in damage to the dowser and is not covered under warranty Performance Warning...

Страница 6: ...ke as shown above or for situations where the unit is to be underslung rotate the yoke 1800 Slide the lamp house sideways into place into the lamp house slot and turn the lamphouse clockwise so the la...

Страница 7: ...types of operation The dowser has the following user adjustable features 1 DMX Address for remote operation 2 Local control for stand alone operation 3 Display on low off DMX Operation The dowser acce...

Страница 8: ...s on then the dowser is receiving a DMX signal and is under DMX control local level is set to 00 If the DMX Status LED is off then the dowser is not receiving a DMX signal OR is under local control Te...

Страница 9: ...duration of the performance 2 If the dowser and MSR ballast are on separate non dim circuits The dowser can be switched independently to the ballast If desired the lamp can be switched on when require...

Страница 10: ...ge to DMX cable Does not respond to DMX control Green LED is not on LED Display is on Damage to DMX cable Local level is set to 00 DMX address Does not respond to DMX control Green LED is on LED Displ...

Страница 11: ...ST Hot Restrike 150W CDM 70W CDM Safe Practice Mains Isolation The unit and luminaire should always be electrically isolated from mains power before re lamping cleaning or servicing Safety Selecon ha...

Страница 12: ...y is to repair replace or service a luminaire subject to a valid warranty claim Under no circumstance will Selecon be liable for direct indirect incidental special or consequential costs or damages in...

Отзывы: