![Selec MFM374 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/selec/mfm374/mfm374_operating-instructions-manual_1236574044.webp)
selec
Online Page Description
Online Page Description
Configuration
19
A/M
MFM374
E
MFM374
VI
A / M
VAF
P
E
PRG
MFM374
E
VAr
VArh
V
L-N
V
L-L
Hz
PF
A
W
Wh
VA
VAh
K
M
L1
L2
L3
AVG
TOT
K
M
L1
L2
L3
AVG
TOT
V
L-N
V
L-L
Hz
PF
A
W
Wh
VAr
VArh
VA
VAh
K
M
L1
L2
L3
AVG
TOT
V
L-N
V
L-L
Hz
PF
A
W
Wh
VAr
VArh
VA
VAh
Press P (
) button, the eighth screen shows:
[
Total active, reactive, apparent
power (Total kW, kVAr, kVA)
kW, kVA,
kVAr
Note
: In 3Ø-3 wire system only Total
will be displayed
Press E ( ) button, the first screen shows:
[
Total active energy (Total kWh)
Note:
1) There are 8 digit for energy
Energy will be displayed in 2 rows, 4 digits in
each with lsb on middle row & msb on top row
Eg: if energy accumulated is 12345.6, top row will
display 12 & middle row will display 345.6
Press E ( ) button, the second screen shows:
[
Total reactive energy (Total kVArh)
Note:
1) There are 8 digit for energy
Energy will be displayed in 2 rows, 4 digits in
each with lsb on middle row & msb on top row
Eg: if energy accumulated is 12345.6, top row will
display 12 & middle row will display 345.6
K
M
L1
L2
L3
AVG
TOT
V
L-N
V
L-L
Hz
PF
A
W
Wh
VAr
VArh
VA
VAh
V
L-N
V
L-L
Hz
PF
A
W
Wh
K
M
L1
L2
L3
AVG
TOT
VAr
VArh
VA
VAh
MFM374
VI
A / M
VAF
P
E
PRG
MFM374
VI
A / M
VAF
P
E
PRG
Press E ( ) button, the third screen shows:
[
Total apparent energy (Total kVAh)
Note:
1) There are 8 digit for energy
Energy will be displayed in 2 rows, 4 digits in each
with lsb on middle row & msb on top row
Eg: if energy accumulated is 12345.6, top row will
display 12 & middle row will display 345.6
Press VI ( ) button for 3 seconds to toggle
between Auto & Manual mode.
Note:
By default unit operates in auto mode.
In auto mode online pages scrolls automatically at
the rate of 5 seconds per page.
In auto mode when any key is pressed, unit
temporarily switches to manual mode and the page
relevant to the key pressed is displayed, also if no
key is pressed for 5 sec, unit resumes auto mode
Configuration
There are 4 dedicated keys labelled as VI, VAF, P, E. Use these 4 keys to enter/exit
the configuration menu / change setting.
Note:
The setting
s
should be done by
a
professional
,
after going through this users
manual and having understood the application situation.
For the configuration setting mode
!
Use
+ keys for 3 sec to enter or exit from the configuration menu.
!
Use or keys for increasing or decreasing parameters value
!
Use
key to go back to previous page
!
Use key to save the setting and move on to next page
X3
20
HMI
X2
X1
X8
selec
21
VI
A / M
VAF
P
PRG
VI
A / M
VAF
P
PRG
17
18
16
19
selec
22
Configuration
V
L-N
V
L-L
Hz
PF
A
W
Wh
VAr
VArh
VA
VAh
VI
A / M
VAF
P
PRG
VI
A / M
VAF
P
PRG
01
02
03
VI
A / M
VAF
P
PRG
18
HMI
X4
X3
X2
23
10
11
12
VI
A / M
VAF
P
PRG
VI
A / M
VAF
P
PRG
VI
A / M
VAF
P
PRG
selec