CONFIGURATION MENU

T

OSCROLL

THROUGHMAINMEOR+KEYS

Netwo

rk

Selecti

on

CT

setti

ng

Relay

Tim

e Settin

g

Hysteresi

s

Password

Factory

set

Un

der

curren

t

CT

Seco

ndary

setti

ng

CT

Prim

ary

setti

ng

Un

der

curren

t

setti

ng

Phase

Asym

metry Phase

Asym

metry

Settin

g

Relay

operati

on

mo

de

Latch

Over

curren

t

setti

ng

Over

curren

t

Trip

tim

e

delay

Reco

very

tim

e d

elay

Pow

er O

N

delay

Curren

t

Asymmetry

Passw

ord

Enabl

e /

Disbl

e

Set

passw

ord

Factory

set

Yes

/ No

MAIN MENU

SUB MENU

Press

+

for 3sec. to enter or exit configuration menu.

SUB MENU

1P2 / 3P3 / 3P4

Not applicable
for 900CPR-1

Network selection (NWK)

Press

to enter sub menu from main menu

DISPLAY

(For 1sec)

Press

+

or

+

to change parameter value

Press

or

to scroll

through sub menu

DESCRIPTION

RANGE

DEFAULT

VALUE

CONDITION

Network

selection

CT setting (CT)

Press

to enter sub menu from main menu

Press

+

or

+

to change parameter value

Press

or

to scroll

through sub menu

CT Secondary
setting

1A / 5A

CT Primary
setting

5 - 999A ( If CT.S is 5A )
1 - 999A ( If CT.S is 1A )

DISPLAY

(For 1sec)

DESCRIPTION

RANGE

DEFAULT

VALUE

CONDITION

A

A

Note :

1) Appearance of shaded menus dependant on selection of other parameters
2) Network selection & phase asymmetry setting not applicable for 900CPR-1

Relay (RLY)

Press

to enter sub menu from main menu

Press

+

or

+

to change parameter value

Press

or

to scroll

through sub menu

DISPLAY

(For 1sec)

DESCRIPTION

RANGE

DEFAULT

VALUE

CONDITION

This option will be
prompted only when OC
option is made ON in
config. menu. OC setting
cannot go below the UC
setting. e.g. If UC is 50A,
OC setting cannot go
below 50A

This option will be
prompted only when UC
option is made ON in
config. menu. UC setting
cannot go above the OC
setting. e.g. If OC is 100A,
UC setting will be limited
till 100A only.

Over current

Over current
setting

ON / OFF

A

<

A

<

ON / OFF

Under current

A

<

A

<

Under current
setting

A

Phase
Asymmetry

ON / OFF

Not prompted for 1P2
network selection (not
applicable for 900CPR-1)

5.0 - 99.9%

A

S

Phase
Asymmetry
Setting

This option will be
prompted only when AS
option is made ON. Not
prompted for 1P2 network
selection (not applicable
for 900CPR-1)

Relay operation
mode

ON / OFF

ON : NO
OFF : NC(During Trip)

(During Trip)

Latch

ON / OFF

If Latch is ON, user has
to reset the unit manually
when fault is removed

0.5A -
10-120% of CT Primary setting

1.19kA

0 – 999A
0-100% of CT Primary setting

S

Press

Key to go to CT Setting (CT) from network selection(NWK)

Press

Key to go to network selection(NWK) from CT Setting (CT)

Doc. name : OP INST 900CPR

OP440-V01(Page 2 of 3)