background image

COMBINED SEARCH DEVICE ST 600,  OPERATING MANUAL 

 

 

14 

The procedure for operating with the main unit 

 

1.  Turn  on  the  main  unit  (fig.2,  pos.2).  The  «MAGN»  indicator  will  light 
(fig.2, pos.4). 
2. Turn on the «CABLE LOCATOR» mode (fig.2, pos.1).  
3. The «TRACKER» indicator will light (fig.2, pos.3). 
4. If necessary, connect headphones to the main unit. 
5. Set a discrimination threshold (fig.2, pos.1). The test signal should not be 
heard at a distance of less than 50 cm from the generator.  
6. Adjust volume level (fig.2, pos.2).  
7. The search starts from the place of connection of the generator.  
8. As the distance from the generator connection point increases, the test 
signal level may decrease due to attenuation. In this case, it is necessary to 
increase  the  level  of  the  generator  signal  (fig.3,  pos.1)  or  lower  the 
discrimination threshold (fig.2, pos.1). 

 
8. STORAGE 

1. Ambient temperature from + 50 to - 10° С 
2. Relative humidity 80% at 30° С 
3. Atmospheric pressure from 630 to 820 mm Hg 

 

9. TRANSPORTATION 

 

Transportation  must  be  made  in  a  shipping  container  subject  to 

protection from exposure to precipitation. Drops and sharp blows resulting 
in mechanical damage are not allowed.  

 
10. WARRANTY 

 

The  manufacturer  undertakes  during  the  warranty  period  (12  months 

from the date of sale) to carry out free repair of ST 600 or its replacement 
on  condition  that  the  customer  observes  the  rules  of  operation, 
transportation  and  storage,  in  the  absence  of  mechanical  damage,  in  the 
presence of a completed warranty certificate. 

Содержание ST 600

Страница 1: ...COMBINED SEARCH DEVICE ST 600 OPERATING MANUAL...

Страница 2: ......

Страница 3: ...tor 5 4 3 Telescopic handle 6 5 Power supply 7 6 Modes 7 6 1 MAGNETIC FIELD DETECTOR mode 7 6 2 CABLE LOCATOR mode 8 7 Operating 12 7 1 Prepare to operating 12 7 2 Operating in MAGNETIC FIELD DETECTOR...

Страница 4: ...rential frequency range kHz 0 04 30 threshold sensitivity A m 2 Hz 1 2 10 7 the detector of the electric field cable locator receiver detector type differential frequency kHz 455 bandwidth kHz 30 thre...

Страница 5: ...vable telescopic handle 1 6 Cable for connecting to computer sockets RJ45 1 7 Cable for connecting to computer sockets RJ12 RJ11 RJ25 1 8 Generator ground cable 1 9 Probe with crocodile clam 1 10 Case...

Страница 6: ...ed to detect low frequency radiation Signals are received by a magnetic antenna 2 Cable locator receiver operating at 455 kHz Signals are received by a differential electric antenna Both antennas are...

Страница 7: ...battery discharge indicator red 10 battery charge indicator green 11 charger connector An adjustable bracket is installed on the device body fig 2 pos 8 The bracket allows you to fix the main unit on...

Страница 8: ...ing cable 6 probe connection socket 7 socket for cables with RJ plugs 4 3 TELESCOPIC HANDLE Removable telescopic handle designed to hold the main unit during operation If necessary examine the removed...

Страница 9: ...controlled by two LEDs Fig 3 p 2 and p 4 When the generator is turned on the red LED lights up Fig 3 p 2 When the battery is low the red LED flashes The generator battery is charged in the off state...

Страница 10: ...30 cm 6 2 CABLE LOCATOR MODE Purpose tracing cables when searching for wire listening devices The mode is implemented by applying a test signal 455 kHz modulated by dual tone low frequency signal to...

Страница 11: ...various types of lines is shown in fig 6 fig 6 Test signal is monitored in a contactless manner using a main unit receiver Operator listens to the received test signal using headphones or built in sp...

Страница 12: ...rientation of the main unit relative to the search plane the level of the signal being listened to will change Fig 8 shows a diagram of the change in the level of the signal being listened when the fr...

Страница 13: ...e distance from the cable to both antennas is equal the receiver is strictly above the cable the signal levels will be also equal In this case the difference in the values of the measured levels will...

Страница 14: ...2 Inspect the wires The insulation of the wires must not be broken the connectors must not be mechanically damaged 3 Install the main unit on the telescopic handle Insert the handle screw into the th...

Страница 15: ...cally switches to the DETECTOR mode The MAGN indicator will light fig 2 pos 4 2 Connect headphones to the main unit fig 2 pos 6 3 Check battery level 4 Adjust the headphone volume by switch fig 2 pos...

Страница 16: ...signal level may decrease due to attenuation In this case it is necessary to increase the level of the generator signal fig 3 pos 1 or lower the discrimination threshold fig 2 pos 1 8 STORAGE 1 Ambien...

Страница 17: ...Russia 192029 St Petersburg Obukhovskoy Oborony 87 7 821 412 3321 7 812 412 4051 http spymarket com info smersh pro...

Отзывы: