COMBINED SEARCH DEVICE ST 600, OPERATING MANUAL
14
The procedure for operating with the main unit
1. Turn on the main unit (fig.2, pos.2). The «MAGN» indicator will light
(fig.2, pos.4).
2. Turn on the «CABLE LOCATOR» mode (fig.2, pos.1).
3. The «TRACKER» indicator will light (fig.2, pos.3).
4. If necessary, connect headphones to the main unit.
5. Set a discrimination threshold (fig.2, pos.1). The test signal should not be
heard at a distance of less than 50 cm from the generator.
6. Adjust volume level (fig.2, pos.2).
7. The search starts from the place of connection of the generator.
8. As the distance from the generator connection point increases, the test
signal level may decrease due to attenuation. In this case, it is necessary to
increase the level of the generator signal (fig.3, pos.1) or lower the
discrimination threshold (fig.2, pos.1).
8. STORAGE
1. Ambient temperature from + 50 to - 10° С
2. Relative humidity 80% at 30° С
3. Atmospheric pressure from 630 to 820 mm Hg
9. TRANSPORTATION
Transportation must be made in a shipping container subject to
protection from exposure to precipitation. Drops and sharp blows resulting
in mechanical damage are not allowed.
10. WARRANTY
The manufacturer undertakes during the warranty period (12 months
from the date of sale) to carry out free repair of ST 600 or its replacement
on condition that the customer observes the rules of operation,
transportation and storage, in the absence of mechanical damage, in the
presence of a completed warranty certificate.