![Selco Genesis 3200 TLH Скачать руководство пользователя страница 219](http://html1.mh-extra.com/html/selco/genesis-3200-tlh/genesis-3200-tlh_instruction-manual_1236514219.webp)
219
8 TEKNISK SPESIFIKASJON
GENESIS 3200 TLH
Strømforsyningsspenning U1 (50/60 Hz)
3x400Vac ±15% 3x230Vac ±15%
Zmax (@PCC)
62m
Ω
*
62m
Ω
*
Treg linjesikring
15A
25A
Kommunikasjonsbuss
DIGITAL
DIGITAL
Maksimal effekt absorbert (kVA)
13.0kVA
13.3kVA
Maksimal effekt absorbert (kW)
12.4kW
12.8kW
Effektfaktor PF
0.95
0.96
Yteevne (
μ
) 85%
85%
Cos
ϕ
0.99
0.99
Maksimal absorbert strøm I1max
18.8A
32.9A
Faktisk strøm I1eff
10.3A
16.5A
Bruksfaktor MMA (40°C)
(x=25%)
/
320A
(x=30%)
320A
/
(x=60%)
260A
230A
(x=100%)
240A
210A
Bruksfaktor MMA (25°C)
(x=60%)
/
320A
(x=65%)
320A
/
(x=100%)
260A
250A
Bruksfaktor TIG (40°C)
(x=30%)
/
320A
(x=40%)
320A
/
(x=60%)
300A
270A
(x=100%)
270A
250A
Bruksfaktor TIG (25°C)
(x=65%)
320A
320A
(x=100%)
260A
250A
Reguleringsområde I2
3-320A
3-320A
Tomgangsspenning MMA Uo
75Vdc
75Vdc
Tomgangsspenning TIG Uo
75Vdc
75Vdc
Spiss-spenning Vp
10.1kV
10.1kV
Beskyttelsesgrad IP
IP23S
IP23S
Isoleringsklasse
H
H
Mål (lxdxh)
620x240x460 mm 620x240x460 mm
Vekt
26.0 kg.
26.0 kg.
Produksjonsnormer
EN 60974-1/EN 60974-3/EN 60974-10
Nettkabel
4x4 mm2
4x4 mm2
Lengde på nettkabel
5m
5m
*
Dette utstyr samsvarer med EN/IEC 61000-3-12 hvis maximum tillatt nettimpedanse ved grensesnittpunktet til offentlig nett (felles koplings-
punkt, PCC) er mindre eller lik “Zmax” fastsatt verdi. Hvis det koples til et offentlig lavspenningssystem, er det installatørens eller utstyrets
brukers ansvar, ved å konsultere operatøren av forsyningsnettverket om nødvendig, at utstyret kan tilkoples.
Содержание Genesis 3200 TLH
Страница 46: ...46 ...
Страница 156: ...156 ...
Страница 198: ...198 ...
Страница 220: ...220 ...
Страница 242: ...242 ...
Страница 269: ...269 ...
Страница 272: ...272 ...