OPL Mini L

code 0000136939

rev. 1.2

2

3.1.4

Programming the lock-out time

-

Enter to programming mode (see par. 3.1.1).

-

Press the

▲ 

key until the green display shows “

3

”.

-

Press the PRG key. The red display’s first digit begins to blink.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. The next digit blinks.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. The next digit blinks.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. All of the display’s digits stop blinking.

-

To save the settings, while none of the display’s digits are blinking, scroll the menu using the

▲ 

key until “

Hld

” appears on the

display and then press PRG key. The pump returns to standby mode and “

on

” appears on the display.

3.1.5

Calibration mode

-

Enter to programming mode (see par. 3.1.1).

-

Press the

▲ 

key until the display shows “

5CAL

”.

-

Press the PRG key, CAL begins blinking.

-

While holding a measuring cup or flask under the outlet of the pump, press the

▲ 

key and release when the pump starts

(display

increases the timer)

. Let the pump runs until desired amount of chemical is dispensed then press the

▲ 

key again to stop. (display

shows the dosing time). The

OPL Mini

run time is now programmed. Repeat these steps if new volume is required.

-

Press the PRG key the display shows “

5CAL

”.

-

To save the settings, scroll the menu using the

▲ 

key until “

Hld

” appears on the display and then press PRG key. The pump returns

to standby mode and “

on

” appears on the display.

3.1.6

Changing access code

-

Enter to programming mode (see par. 3.1.1).

-

Press the

▲ 

key until the display shows “

o+

old access code

”.

-

Press the PRG key the display shows “

n+

old access code

” and the red display’s first digit begins to blink.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. The next digit blinks.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. The next digit blinks.

-

Press the

▲ 

key until the blinking digit displays the desired value.

-

Press the PRG key. All of the display’s digits stop blinking.

-

To save the settings, while none of the display’s digits are blinking, scroll the menu using the

▲ 

key until “

Hld

” appears on the

display and then press PRG key. The pump returns to standby mode and “

on

” appears on the display.

3.2

SETUP TRIGGER HI-LO

-

Enter to programming mode (see par. 3.1.1).

-

Press the

▲ 

key until the display shows “

4 HI

” or “

4 LO

”.

-

Press the PRG key and “HI” or “LO” readout will blink.

-

Press

▲ key

to select if a signal is “

LO

(20÷240 VAC)

or “

HI

(70÷240 VAC)

.

-

Press PRG key and the display stops blink

-

To save the settings, while none of the display’s digits are blinking, scroll the menu using the

▲ 

key until “

Hld

” appears on the

display and then press PRG key.

The signal trigger has a filter of 5 seconds.

3.3

EXITING FROM PROGRAMMING

To exit programming and return to the main menu, scroll the menu using the

▲ 

key until “

ESC

” appears on the display. Now press PRG key.

The pump returns to standby mode and “

on

” appears on the display. None of the modified settings are saved.

3.4

PRIMING MODE

On the standby mode (the display shows the message: on) push the

▲ 

key the pump starts dosing for one minute and the display shows “

Pri

”.

To stop the pump before the priming time is elapsed, press

▲ key to stop.

3.5

MOTOR STOPPING

In case the motor is excessively overloaded (for ex. a tubing breaks) the pump executes stop/restart motor cycles (the stop time increases at
every STOP: 0.5 sec .

10 sec.) to avoid the overheating of the same pump.

During the motor stop the display visualizes: “

1Alr

4.0

DISPLAY

As soon as the pump is powered, the display shows “

8888

” for approximately 0.3 seconds, during which the pump runs a check:

If the parameters cannot be read properly from EEPROM, the display shows “

FAIL

“ and the pump remains on standby.

The default parameters can be reset using the

▲ 

key (pressed for 4 seconds). The default parameters are:

Delay time = 005
Dosing time = 055
Lock-out time = 000
Trigger signal = HI
Calibration = CAL
Old password = 000

After the default parameters have been reset, these parameters can be modified from the programming menu (see chap. 3).

5.0

ACCESSORY

Available a remote control, the code is 9900700097.