14
as follows:
1.
Press for more than 20 seconds the key ‘
‘; the display will
show the first user parameter ‘
AFr
‘.
2.
Press the ‘
‘ button repeatedly to scroll through the user
parameters:
Antifreeze Setting
‘
AFr
’
Internal sensor Offset setting
‘
OFS1
’
Remote sensor Offset setting
‘
OFS2
’
Regulation sensor choice setting
‘
rEG
’
3.
Press the ‘
OK
’ button to modify the selected parameter.
4.
Configure the data associated with each individual parameter as
illustrated below.
5.
To exit the user parameter programming mode, press the ‘
OK
’
button to confirm the changes made or else wait 10 seconds
without pressing any button.
‘AFr’ ANTIFREEZE SETTING
The Antifreeze function allows you to select a minimum temperature
to be maintained when the chronostat is off, so as to protect both the
room and the equipment when the room temperature falls below the
set value. The device leaves the factory with the Antifreeze function
set on 3°C.
IMPORTANT: the function is active only when the device has
been set in the heating mode.
To set the Antifreeze temperature, carry out the following steps:
1.
Select the parameter ‘
AFr
’ and press the ‘
OK
’ button.
2.
The display will show the previously set Antifreeze temperature.
3.
Press buttons
‘ ’ and ‘ ‘
to change the setting (between
OFF, 0.5°C..25°C);
every change will be automatically
Setting the Comfort and Economy modes
The timer thermostat has 24 switches (
A
on Fig. 1), situated
alongside the display, for programming operation in the ‘Comfort’ or
‘Economy’ modes at different times of the day.
When you want the timer thermostat to operate in the comfort mode,
for example during the daytime, move all the switches corresponding
to the desired time interval over to the right.
If you want the timer thermostat to operate in the economy mode,
for example during the nighttime, just move all of the switches
corresponding to the desired time interval over to the left.
In this case it is sufficient to remember the following rule:
Switches positioned to the right: The comfort setting is enabled in
the automatic operating mode.
Switches positioned to the left: The economy/night setting is
enabled automatic operating mode.
Each switch corresponds to the interval falling between the times
printed above and below the switch itself.
For example, note that the time interval from 00 to 05 is controlled by
a single switch, whereas from 05 to 09 in the morning settings can
be made at half-hour intervals. For the rest of the day, the selectable
time intervals are one hour each (
A
on Fig. 1).
The Comfort temperature is set by means of knob ‘
‘ (Sun), whereas
the Economy temperature is set by means of knob ‘
‘ (Moon).
Normally, in order to have a reduced temperature at nighttime, knob
‘
‘ will be set on a lower value than knob ‘
‘.
SETTING THE USER PARAMETERS
To enter the mode for setting the chronostat parameters, proceed
ITALIANO
DEUTSCH
FRANÇAIS
ESPAÑOL
PORTUGUÊS
ENGLISH
Содержание FREETIME PLUS
Страница 2: ...2 ...
Страница 6: ...6 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 WIST02000AAN 023664A0 290514 ...