Seitron BE COOL R1 Скачать руководство пользователя страница 1

USE AND MAINTENANCE

Refrigerant gas leak detector

BE COOL R1 

Содержание BE COOL R1

Страница 1: ...USE AND MAINTENANCE Refrigerant gas leak detector BE COOL R1...

Страница 2: ......

Страница 3: ...ECHANICAL DESCRIPTION 6 4 0 OPERATION 6 4 1 Gas detection method 7 4 2 Automatic and manual autozero setting 7 4 3 Display of instrument sensitivity level 8 4 4 Leak alarm acoustic alarm silencing 8 4...

Страница 4: ...ty for any content or printing errors Respect your environment think before you print the full manual 1 2 Safety Warnings WARNING Read the information carefully and set up appropriate measures to ensu...

Страница 5: ...R123 R124 R502 HCFCs for example R134a R404a R410a R407C R32 HCs for example R600a R290 HFOs for example R1234YF Sensor life 1 year Autozero automatic manual Probe length 420mm 16 5 in Battery life 7...

Страница 6: ...UTE Turns on off the instrument acoustic signaling SENS SENS button if pressed repeatedly cycles between the three instrument sensitivities High Medium Low 4 0 OPERATION Press the ON OFF button this w...

Страница 7: ...tection method The figure below exemplifies the method of leak detection Bend the flexible end of the instrument into the shape that best suits the case at hand slowly move the probe closer to the lea...

Страница 8: ...robe only a service center can repair this fault 2 After solving the problem of the missing or failed probe the instrument needs to redo the warm up phase 3 When multiple faults occur simultaneously t...

Страница 9: ...ntact with an environment with a concentration higher than 30 000 ppm refrigerant gas 7 0 TECHNICAL FEATURES Power supply 3 x 1 5V AA alkaline batteries supplied or 3 x 1 5V AA rechargeable batteries...

Страница 10: ......

Страница 11: ......

Страница 12: ...Seitron S p A a socio unico Via del Commercio 9 11 36065 MUSSOLENTE VI ITALY Tel 0424 567842 info seitron it www seitron com...

Отзывы: