5. INSTALLATION
5.1 SETTING UP THE LED LIGHT SOURCE
Place the LED light source on a stable surface (cart, counter, stand, etc.).

NOTE:   Avoid places where the light source may be splashed with liquid.
 

Absolutely DO NOT use in any environment with explosive or flammable gases.

 

DO NOT block the venting grids of the LED light source.

Make sure the power switch is in OFF position.
Connect AC power cord to the power inlet located on the rear panel of the light source.

CAUTION:

 Use only cords provided with the light source.

Plug the AC power cord into a wall outlet using the three-prong plug supplied with the unit.

CAUTION:

 To prevent electric shock, connect power cords of peripheral equipment through medical isolation 

transformers.

NOTE:   When using medical isolation transformer, be sure to check the transformer power ratings.

Make sure that the power cord is connected to the main power with three-prong plug (USA use UL2601-1 rated 
isolation transformers and/or power strips only).

CAUTION:

 When used in clinical or residential areas near radio or TV units, this equipment may be subjected to radio 

interference. To avoid adverse electromagnetic effects, DO NOT operate this equipment near RF energy equipment.

5.2 CONNECTING THE FIBER OPTIC CABLE
Turn intensity control to the minimum setting. Connect the light cable to the instrument and then plug the light cable 
endfitting into the port on the front panel.

6. OPERATION
6.1 POWERING UP THE LED LIGHT SOURCE
To operate the LED light source: Turn on the power switch. The indicator on power switch will light.

6.2 LIGHT BRIGHTNESS DISPLAY AND CONTROL
The light brightness adjustment enables the user to obtain a brighter or darker illumination of the object of observation.
Adjust the light intensity by turning the intensity control knob.

7. CLEANING
NOTE:
 Always disconnect the power cord before cleaning the system.

The unit can be cleaned with any cleaning agent, which is used for external cleaning of electric equipment, according to 
instructions given by the manufacturer of the cleaning solution.

Do not allow excessive moisture or liquids to come in direct contact with the unit.

Do not use cleaning agents that are not permitted for use with plastics, i.e., ammonia, acetone, salty acids (HCl), etc.

Do not allow cleaning agents or liquids to enter the unit outlets.

8. DISINFECTION
8.1 DISINFECTING THE UNIT

NOTE: Always disconnect the power cord before cleaning the system.

Use any disinfectant agents which are commonly applied while disinfecting surfaces of electric medical equipment. Such 

Содержание Evolution xR6

Страница 1: ...PRECISION MICROSCOPES EVOLUTION XR6 LED Dental Microscope Slim Model User s Manual...

Страница 2: ...nts Table of Contents 2 Installation Assembly 3 LED Illumination Instructions 8 LED Warranty 13 Interpupillary Distance Adjustment 13 Parfocalizing 14 The Color Filter and Cleaning 15 Dimensions 16 Pa...

Страница 3: ...ve the base weights from the weights box and insert the weights one at a time into the bottom of the base Align the pins with the holes and depress the thumb lock button to put the weights into place...

Страница 4: ...into the base insert the Light Housing Light Source portion of the microscope into the top of the pole This is where the illumination system is housed Make sure that the light source is secured while...

Страница 5: ...and the Liquid Light Guide cable is secure add the extension piece into the top of the Pantographic Arm on the under side Be sure to loosen the black knob and pull plunger on the Pantographic Arm in o...

Страница 6: ...ree coupler coming off the optic pod Screw down the white knob 10 Insert the Liquid Light Guide cable into the light port opening on the Optical Pod 11 Secure the Binocular Head onto the Optical Pod b...

Страница 7: ...rn counter clockwise to add tension clockwise to release tension This may need to be done if camera video are added to the scope This will increase or decrease the tension to desired function for user...

Страница 8: ...oxygen or nitrate oxide To prevent any potential electro magnetic interference do not use any kind of cellular phone near the light source This product should be used only with type BF endoscopic ins...

Страница 9: ...ation Continuous operation Water Resistant Not Protected Equipment IPX0 Operating Environment Temperature Relative Humidity Air Pressure 0 to 40 C 32 to 104 F 0 to 85 rh non condensing 700 to 1060 hPa...

Страница 10: ...tion 1 AC main inlet Accepts AC power cord 2 Fuse 2A 250V 1 4 x 1 time delay 3 Grounding Connector For potential equalization 4 Venting grids Allows adequate ventilation and cooling of the light sourc...

Страница 11: ...equipment near RF energy equipment 5 2 CONNECTING THE FIBER OPTIC CABLE Turn intensity control to the minimum setting Connect the light cable to the instrument and then plug the light cable endfittin...

Страница 12: ...ack unit in a sturdy carton and ship it to the factory Please include a note describing the defects your name telephone number and a return address Warranty does not cover equipment subject to misuse...

Страница 13: ...s under this warranty are limited to the repair replacement or reimbursement of the product only and in no event is Seiler Instrument liable for any consequential or special damages or costs related t...

Страница 14: ...33 60 80 48 03 4 1 28x 15 78 19 87 16 23 12 88 13 82 14 41 18 52 14 71 11 09 13 91 23 08 18 40 9 22 11 58 27 78 22 10 6 91 8 75 37 10 29 27 5 1 6x 19 70 24 83 13 00 10 30 17 28 21 76 14 80 11 75 13 8...

Страница 15: ...cotton swab in each circular friction avoiding spreading again the impurities The Objective lens can be protected by use of an objective protector 6132000 It is placed under pressure in the external...

Страница 16: ...Base Length 27 5 700mm Base Width 25 635mm Caster 4 101 6mm Depth 11 8 300mm Height floor to light housing 52 Height 70 Extension Arm 6 150mm Length of Pantographic Arm 26 660mm Angle Arm 14 355 6mm...

Страница 17: ...17 Parts Breakdown Handles Magnification Turret Binocular Head LED Illumination System 45 Degree Pantographic Arm Locking Knob Fine Focus Knob Objective Lens Tension Knob Green Orange Filter...

Страница 18: ...uses 3amp 5x20mm Cylindrical Slo Blo 250VAC Illumination Bulb LED Optical Details Standard Setup Optional Setup Objective Lens 250mm 175 400 mm Eyepieces 10x 12 5x 26x 20x Diopter Setting 6 to 6 NA Fi...

Страница 19: ...__________________ Serial Number ________________________________________________________ Date Purchased _______________________________________________________ Location Purchased ____________________...

Страница 20: ...ting Sales Representative nbas seilerinst com or ext 345 Tony Leise Technical Support Product Information tleise seilerinst com or ext 363 Sandy Jeremich Office Administrator Logistics sjeremich seile...

Отзывы: