  Rechargeable battery and electronic circuit

 

11   RECHARGEABLE BATTERY UNIT

•  How to install

 

Set the “B” portion of the (-) lead terminal 

of the rechargeable battery unit to the 
groove of the main plate, and then, set the 
“A” portion of the (-) lead terminal to the 
guide post of the main plate.

Notes: 
*  Handle the rechargeable battery unit with care 

so as not to short-circuit its (+) and (-) terminals.  
Otherwise, the rechargeable battery unit will 
be deteriorated.

*  Never wash the rechargeable battery unit as 

it is an electronic part.

 

  9   

CIRCUIT BLOCK COVER

•  How to remove

 

Remove the two circuit block cover screws, 

and then, release the two hooking portions 
marked with the arrows in the illustration at 
right from the main plate.

•  How to install

 

Set the circuit block cover so that the two 

hooking portions marked with the arrows in 
the illustration at right catch the main plate 
securely, and then, tighten the circuit block 
cover screws.

Rechargeable battery unit

Guide post

“A” portion of

the (-) lead terminal

“B” portion of

the (-) lead terminal

TG V116A.indd   8

11/08/01   9:55

Содержание V116A

Страница 1: ...ond intervals 4002 909 1 20 1 60 K Circuit block Less than 0 16 A Movement Less than 0 22 A Time setting hand position adjustment resetting the circuit Free Outside 11 6 mm x 15 55 mm Casing 11 6 mm x...

Страница 2: ...le battery decreases it is necessary to have the watch repaired Environment Light source Illumination lux Time required for full charge Time required for steady operation Time to charge 1 day of power...

Страница 3: ...ands 3 Case ring 2 PCS Movement 4020 582 Solar cell unit 7 0271 946 Hour wheel 6 0491 735 Dial washer 5 4246 644 Solar cell lead terminal 2pcs 4 Please see the remarks on the following pages Disassemb...

Страница 4: ...k cover screw 9 4461 526 Circuit block cover 24 0282 804 Clutch wheel 25 4239 909 Rotor stator 26 0100 578 Main plate 21 0389 909 Setting lever spring 22 0383 806 Setting lever 23 0351 861 Setting ste...

Страница 5: ...UE in order to choose corresponding parts 3 CASE RING 8277 2020 The type of case ring is determined based on the design of cases Check the case number and refer to the Parts Catalogue web site to choo...

Страница 6: ...l securely as it easily comes out of position 3 CASE RING Note The complete case ring is constructed with 2 same half case rings One is used for the 12 o clock side and the other one is used for the 6...

Страница 7: ...removing or installing the solar cell unit take care not to damage the solar cell If the solar cell is damaged its power generating capacity may be greatly decreased In that case check the output volt...

Страница 8: ...chargeable battery unit will be deteriorated Never wash the rechargeable battery unit as it is an electronic part 9 CIRCUIT BLOCK COVER How to remove Remove the two circuit block cover screws and then...

Страница 9: ...ition and lubricating Refer to the illustrations below for the setting position and lubrication of the respective wheels Lubriccating Types of lubricant Watch oil AO 3 Watchi oil AO 2 Lubricang quanti...

Страница 10: ...ustration below for the setting position and lubrication of the respective parts Have the spring portion of the yoke securely catchtheprotrudedportionofthemainplate A portion in the illustration Note...

Страница 11: ...cuit the minus probe and circuit block cover 4 After checking that a stable measurement is obtained with the tester connected read the current consumption As the hands move at 20 second intervals 3 to...

Страница 12: ...urement value may be obtained 3 After checking that a stable measurement is obtained with the tester connected read the current consumption Structure of the circuit block Coil output terminal Crystal...

Страница 13: ...asshownintheillustration atrighttomeasurethevoltageoftherechargeablebattery before recharge initial voltage 2 Place the watch at a distance of 5 cm under a fluorescent light of 15 to 20 watts and char...

Страница 14: ...the table below to determine whether the recharging function is normal or not Initial voltage and guidelines of normal defective decision Initial voltage Guidelines of normal defective decision 0 5 V...

Страница 15: ...times Setting mechanism function of the time setting Make sure that it has a click at the 1st click position and the stem is not pulled off Pull out the crown to the 1st click then turn it Setting mec...

Страница 16: ...ESIST 20BAR 20 BAR SCUBA DIVER S AIR DIVER S 150 m 18 75 BAR 150 m times 0 125 SCUBA DIVER S AIR DIVER S 200 m 25 BAR 200 m times 0 125 He GAS DIVER S 300 m 37 5 BAR 300 m times 0 125 He GAS DIVER S 6...