TECHNICAL GUIDE
Cal. V115A
14/16
3. After recharging for 30 minutes, apply the probes of
the tester in the same manner as in step "1" above, and
measure the rechargeable battery voltage while keeping
the watch exposed to the light.
4. Refer to the table below to determine whether the recharging function is normal or not.
[ Initial voltage and guidelines of normal/defective decision ]
Initial voltage
Guidelines of normal/defective decision
0.5 V - 1.00 V
The battery is normal if the rechargeable battery voltage obtained
after recharge is more than 1.2 V.
1.01 V - 1.2 V
The battery is normal if the rechargeable battery voltage has in-
creased more than 0.08 V after recharge.