Changing Printer’s Serial Baud Rate Settings 

 
Some embedded systems have serial ports with slow baud rates.  And sometimes these baud rates are 
incompatible with the default baud rates of the Smart Label Printers.  The 440 and 450 printers have an 
EEPROM that can store the default baud rate that the printer should use when it powers up.  Within the 
standard application install is a program called “SlpSelect.exe”.  Executing SlpSelect.exe as described 
below will present a private interface for changing the baud rate of attached printers.

 

 

1.

 

Attach an SLP 440 or SLP 450 to the serial port of your computer.  (

The USB cable should 

not be attached.)

  If your printer did not come with a serial cable please contact support.  You 

may qualify for a free serial cable from Seiko Instruments USA Inc. 

2.

 

Execute SlpSelect.exe /default [port] [baudrate] 

a.

 

port is one of 

COM1, COM2, COM3 or COM4

 

b.

 

baudrate is 

9600, 19200, 38400, 57600, 115200

 

For example: 

> SlpSelect.exe /default COM1 9600 

3.

 

Follow the instructions on-screen. 

 

 

 
Factory baud rate for the SLP 440 is 115,200.  Factory baud rate for early SLP 450 models is 38,400 
and 115,200 for later models. 

Содержание SLP 100/410

Страница 1: ...SEIKO INSTRUMENTS USA INC SMART LABEL PRINTER ADMINISTRATION NOTES 6 6 DOCUMENTATION SLP 100 410 SLP 200 420 SLP 240 430 SLP 440 SLP 450 2007 Seiko Instruments USA Inc...

Страница 2: ...es 4 Specifying Alternate Paths 6 Program Configuration Settings 6 External Label Processing 7 Remote Desktop Connection 8 Smart Label Run time Diagnostic Logging 9 Turn debugging on 9 Turn driver deb...

Страница 3: ...the name trademarks service marks or logos of SII may be used to endorse or promote products derived from the SII Software without specific prior written permission from SII Except as expressly stated...

Страница 4: ...folder ID CSIDL_COMMON_DOCUMENTS Typical path C Documents and Settings All Users Documents Files Smart Label Printer LABELS SLL Label Library data base PublicData Windows special folder ID CSIDL_COMMO...

Страница 5: ...s changed the Smart Label program may still look for the file in the original location This is because the path of the current label library is saved in the SlpConfig xml file You may also need to cha...

Страница 6: ...a Paths SLP_Admin Note that any or all of the four paths may be specified in this file A path specified in this file will override the corresponding default path Likewise any path s not defined in thi...

Страница 7: ...last four digits e g 0001 are incremented for each label ExecuteProgram Path to the user program to execute The program will be executed with a command line that includes the path of the Label Informa...

Страница 8: ...or similar environment the printer name may be decorated each time a user creates a new session The decoration is usually a suffix following the printer name To delimit the actual printer name from t...

Страница 9: ...registry script files located in the same folder as the Smart Label application which may be executed to enable or disable Diagnostic logging Turn debugging on Run SLPDebugOn reg double click it Turn...

Страница 10: ...eg file or run the reg files from an elevated command prompt Values Turn driver debugging on Run SLPDriverDebugOn reg either double click or on Vista type the name of the file with path if necessary i...

Страница 11: ...esent a private interface for changing the baud rate of attached printers 1 Attach an SLP 440 or SLP 450 to the serial port of your computer The USB cable should not be attached If your printer did no...

Отзывы: