STP-H803C1 Instruction Manual (excerpt)
1.2 Specifications
for
the STP Control Unit
Table 1.2 Specifications for the STP Control Unit (1/2)
Item Specifications
Input voltage
V AC
200 to 240
±
10%
Without the TMS unit:
VA
Max. 850
Input power
With the TMS unit:
VA
Max. 1,200
Input frequency
Hz
50/60
±
2
Leakage current value
mA
Max. 3.5
Input phase
Single phase
Rated current
15A
Main breaker spec.
AIC: Ampere Interrupting
Capacity
1000A(AC240V, 50/60Hz)
Motor drive system
3-phase DC brushless motor driver
Output voltage under rated operation
V AC
79
Output frequency under rated operation
Hz
575
Ambient temperature range
°C
0 to 40
Storage temperature range
°C
- 25 to + 55
9
Dimensions
mm
W210
×
H132.5
×
D401.6
TMS control unit
Internal
Operation switches
START switch
(flat panel switch, green)
STOP switch
(flat panel switch, dark gray)
RESET switch
(flat panel switch, gray)
SELECT switch
(flat panel switch, gray)
UP switch
(flat panel switch, gray)
DOWN switch
(flat panel switch, gray)
ENTER switch
(flat panel switch, gray)
MANUAL/REMOTE changeover switch
(slide switch, black)
Panel indication lamps
ACCEL. lamp
(green LED)
NORMAL lamp
(green LED)
BRAKE lamp
(green LED)
TEMP CTRL lamp
(green LED)
POWER lamp
(green LED)
FAILURE lamp
(red LED)
REMOTE lamp
(green LED)
Panel display
LCD panel (20
×
2 characters)
*1
: The points of difference between the STP-H803/H1303 Series and the STP-H803C1.
*2
: Mass is a value of state that the only standard accessory was installed (except the optional accessory).