3-20
3.6.5 Head Activation Pulse Term Coefficient
Make adjustments using the head activation pulse term coefficient (equal motor drive frequency) as the
printing density changes by the printing speed.
According to equations (8), calculate compensation coefficient C of the activation pulse.
Equation (8):
C = 1 – 0.5/(0.8 + W)
W = (1000/motor drive frequency) – activation pulse for the previous 1 block
3.6.6 Determination of Activation Pause Time
In order to protect the thermal head heat elements, when the same heat element dots are activated
continuously on the successive dot line, determine the pause period (the time from the end of the the
preceding activation to the start of the current activation) which meets equation (9) to secure the pause
time.
Equation (9):
W’ > 0.15 (ms)
W’: Activation pause time for 1 dot line (ms)