background image

NREY922C

10-2010

CAL. Y922 , YK30 , YK31 , YK32 , YK33 , YK34

CAL. Z001 , Z002 , Z003 (R23 SERIES )

D I S P L AY   A N D   B U T T O N   O P E R AT I O N

C H A R A C T E R I S T I C S

1. Time/calendar display

:   Hour, minute,

second, date, day of the week and month.

2. Automatic calendar adjustment

:  Calendar

adjusts automatically for odd and even
months except February of leap years.

3. Time indication

:  Changeover between 12-

hour and 24-hour indications is possible.

4. Stopwatch

:  24-hour stopwatch with 1/100

second readout up to 40 minutes and with 1
second readout after the first 40 minutes.
Split time measurement is available.

5. Alarm

:  The alarm rings at the designated

hour and minute with “beep, beep” for 30
seconds.

6. Hourly time signal

:  Can be set to ring every

hour on the hour with a single “beep”.

7. Illuminating light (for Cal. YK30, YK31,

YK32, YK33, YK34 & Z001)

:   The light evenly

illuminates the display in the dark.

Button B:

Calendar (month, date and day) display in
the time/calendar display.

Start/stop in the stopwatch function.

Selection of the digits to be adjusted in the
a l a r m   s e t t i n g   f u n c t i o n   a n d   t h e   t i m e /
calendar setting function.

Button C:

Alarm display in the time/calendar display.

Split/Split release/Reset in the stopwatch
function.

Setting the digits in the alarm setting function
and the time/calendar setting function.

Stopping the alarm in any display.

Button B while keeping Button C pressed:

Engagement and disengagement of the alarm
and the hourly time signal.

Button C while keeping Button B pressed:

Changeover of the calendar (month and date)
display.

Buttons B & C:

Alarm test in the time/calendar display.

H O W   T O   S E T   T H E   D U A L   C A L E N D A R
D I S P L AY

1

Press Button B to show the calendar (month,
date, and day) display.  The calendar display
is shown while Button B is kept pressed.

2

The month and the date change places with
each other with each press of Button C while
keeping Button B pressed.

*

In the 12-hour indication, “A” (AM)/“P” (PM)
mark is displayed.  In the 24-hour indication,
there is no indication.

H O W   T O   U S E   T H E   S T O P WAT C H

1

Press Button A to show the stopwatch display.
(The stopwatch indicator starts flashing.)
The stopwatch can measure up to 24 hours
and is displayed in minutes, seconds, and
1/100 seconds up to 40 minutes, and in
hours, minutes, and seconds after the first
40 minutes.  (The 1/100 second indicator
flashes during the first 40 minutes.)
When the measurement is over 24 hours, the
stopwatch will be reset to “0:00oo” and start
counting again.

2

Reset the digits to “0:00oo” before using the
s t o p w a t c h .   W h e n   t h e   s p l i t   a n d   t h e
stopwatch indicators are flashing, press
Button B to check that the stop indicator
starts flashing, and then press Button C twice
to reset the digits to zero.

3

When measuring a long period of time, return
the stopwatch to the time/calendar display
after the stopwatch starts to prevent any
possible mistaken operation.

*

W h e n   B u t t o n   B   o r   C   i s   p r e s s e d   i n   t h e
stopwatch display, a single “beep” sounds
to confirm the operation.

S t a r t

S t o p

R e s t a r t

              Stop      Reset

H O W   T O   S E T   T H E   A L A R M

H o u r   s e t t i n g

M i n u t e   s e t t i n g

1

Press Button A for 2 seconds to activate the
a l a r m   s e t t i n g   f u n c t i o n .     ( T h e   a l a r m   s e t
indicator starts flashing.)

2

Press Button B to activate the “Hour” or
“Minute” setting.  The display changes in the
following order with each press of Button B.

3

One digit (flashing) is advanced with each
press of Button C.  The digits are advanced
quickly by keeping Button C pressed.

4

After all the adjustments are completed,
press Button A to return to the time/calendar
display.
(The display returns directly to the time/
c a l e n d a r   d i s p l a y   a n d   n o t   t o   t h e   t i m e /
calendar setting.)

C

C

B

C

B

S t a r t

F i n i s h   t i m e

of 1st

c o m p e t i t o r

S t o p

F i n i s h   t i m e

of 2nd

c o m p e t i t o r

R e s e t

M e a s u r e m e n t   b e t w e e n   t w o   c o m p e t i t o r s

F i n i s h   ( F i r s t   r u n n e r )

F i n i s h   ( S e c o n d   r u n n e r )

Note

: When setting the hour digits, be sure to

check that the “A” (AM)/“P” (PM) mark is
correctly set.

[Cal. YK32 / Z001]

H o u r

M i n u t e

A

E L   b u t t o n

H o u r l y   t i m e

s i g n a l   m a r k

A l a r m   m a r k

D a y   i n d i c a t o r

S e c o n d

E L   b u t t o n

C

B

[Cal. YK33]

[Cal. YK30 / YK31]

H o u r

A

E L   b u t t o n

H o u r l y   t i m e

s i g n a l   m a r k

A M / P M   i n d i c a t o r
1 2 - h o u r / 2 4 - h o u r   i n d i c a t i o n

E L   b u t t o n

A l a r m   m a r k

D a y   i n d i c a t o r

S e c o n d

C

B

M i n u t e

B

A l a r m /
H o u r l y   t i m e   s i g n a l     m a r k

H o u r

A

S e c o n d

C

M i n u t e

D a y   i n d i c a t o r

[Cal. YK34]

H o u r

S e c o n d

M i n u t e

E L   b u t t o n

A

C

B

A

M i n u t e

B

H o u r

[Cal. Y922 / Z002 / Z003]

H o u r l y   t i m e

s i g n a l   m a r k

D a y   i n d i c a t o r

A l a r m   m a r k

C

S e c o n d

Button A:

Selection of the display.

The selection is made in the following order:

D a y

i n d i c a t o r

A l a r m / H o u r l y   t i m e

s i g n a l   m a r k

A M / P M   i n d i c a t o r

A

A

T i m e / c a l e n d a r   d i s p l a y

S t o p w a t c h   d i s p l a y

P r e s s

B u t t o n   A

f o r   2   s e c .

A

A

A l a r m   s e t t i n g

T i m e / c a l e n d a r   s e t t i n g

B

C

M o n t h

D a y

B

C

D a t e

D a y

M o n t h

D a t e

A

S t o p w a t c h

i n d i c a t o r

S t o p   i n d i c a t o r

S p l i t   i n d i c a t o r

1 / 1 0 0   s e c o n d
i n d i c a t o r

B : S t a r t / S t o p

C :   S p l i t /
         Split release/

 Reset

M i n u t e

S e c o n d

1 / 1 0 0   s e c o n d

A

C

A l a r m   s e t   i n d i c a t o r

B

H o u r

M i n u t e

“ A ”   ( A M )

S t a r t

Measurement and release of split time can be
repeated by pressing button C.

Split time measurement

B

B

C

C

C

S p l i t

S p l i t

R e l e a s e

S t o p

R e s e t

Restart and stop of stopwatch can be repeated
by pressing button B.

Accumulated elapsed time measurement

B

B

B

B

C

B

BLUE

10.8.18, 5:19 PM

Page 1

Adobe

Отзывы: