Troubleshooting
Possible causes
Solutions
Reference pages
Misalignment of
time and hands
The seconds hand position indicating
the reception result is incorrect
The standard position of the seconds hand is incorrect. (This can occur when
the position of the seconds hand is incorrect due to external influences.)
①
The automatic hand position alignment function is activated to automatically adjust the position.
Please use the watch as it is. The automatic hand position alignment function is activated once a
minute for the seconds hand.
②
When misalignment of the hand is not adjusted, consult the retailer from whom the watch was
purchased.
The watch temporarily gains or loses
time.
The automatic time adjustment function has not been activated for a few days.
If the energy stored in the watch is insufficient, the automatic time adjustment function may be activated
once in 3 days.
To adjust the time immediately, carry out “manual time adjustment.”
The watch received an incorrect time due to external factors (erroneous
reception).
①
Receive GPS signals in a place where GPS signals can be more easily received.
②
Adjust the time zone as necessary.
The watch is left in an extremely high or low temperature place for a long time.
①
If the watch is returned to a normal temperature place, the accuracy will be recovered.
②
If the time is incorrect after that, manually adjust the time as necessary.
③
If the watch is not recovered, consult the retailer from whom the watch was purchased.
The time is gained (lost) 1 hour
The setting for the time difference (including DST (daylight saving time or
“summer time”)) does not match the time of the current location.
Reset the time difference if different from the time of the current location.
→ How to perform manual time difference setting (selection)
Charging the
solar battery
The stopped watch was exposed to an
adequate light for longer than the time
required to fully charge the watch,
however, it does not resume its normal
1-second interval movements.
The amount of exposed light is too weak.
The time for charging the watch is not sufficient.
The time required for charging the watch depends entirely on the amount of exposed light the watch
receives.
Refer to "Standard Charging Time" to charge the watch.
The seconds hand is stopped even
when the watch is charged for longer
than the time required to fully charge
the watch
The watch was not charged for a long time and has been discharged
completely.
Contact the retailer from whom the watch was purchased.
−
Misalignment of
date
After the reception is successful, the
time is correct but the date is incorrect.
The preliminary position of the date is out of alignment.
This problem occurs when the preliminary position of the date is out of
alignment due to external influence etc.
Adjust the preliminary position of the date to the correct position “1” (the first day of a month).
-