Seiko 6R15C Скачать руководство пользователя страница 18

TECHNICAL GUIDE

Cal.6R15C/D

 Accuracy test

Measure the rate in three different positions within 30 minutes after the watch is fully wound up (wait
approximately for 5 minutes after winding up in order to get a stable oscillation of the balance) and
make sure the value shows within the range in the table below.

Measure the rate in dial-up position after 24 hours from fully wound up (T24) and check the rate
difference with the rate in dial-up position when it is fully wound up (T0). Make sure that the value of
T24-T0 shows within the range of the isochronism in the table below.

Instantaneous rate at T0

Isochronous fault

Fully would condition)

Testing

 

positions Dial upward

6 o'clock 

9 o'clock 

Dial upward

at the top

at the top

Measurement

(Daily rate in

±

 

20 s/d

±

 

30 s/d

±

 

30 s/d

 

±30 s/d

  

seconds

s/d

● 

Accuracy of Mechanical Wataches

The accuracy of mechanical watches is indicated by the daily rates of one week or so.

When affected by external strong magnetism, a mechanical watch may loss/gain time temporarily.

● 

Duration time test

Check the Power reserve of the watch after the mainspring is fully wound up and leave it oon natural

10/16

condition with the dial-up position. Make sure that the watch runs approximately 41 hours until it stops.

18/18

The parts of the watch may become magnetized depending on the extent of the effect. In such a case,
consult the retailer from whom the watch was purchased since the watch requires repair, including
demagnetizing.

Standard rate

for measurement

The accuracy of mechanical watches may not fall within the specified range of time accuracy because
of loss/gain changes due to the conditions of use, such as the length of time during which the watch is
worn on the wrist, arm movement, whether the mainspring is wound up fully or not, etc.

The key components in mechanical watches are made of metals which expand or contract depending
on temperatures due to metal properties. This exerts an effect on the accuracy of the watches.
Mechanical watches tend to lose time at high temperatures while they tend to gain time at low
temperatures.

In order to improve accuracy, it is important to regularly supply energy to the balance that controlsthe
speed of the gears. The driving force of the mainspring that powers mechanical watches varies
between when it is fully wound and immediately before it is unwound. As the mainspring unwinds, the
force weakens.
Relatively steady accuracy can be obtained by wearing the watch on the wrist frequently for the
selfwinding type and winding up the mainspring fully everyday at a fixed time to move it regularly for the
wind-up mechanical type.

Содержание 6R15C

Страница 1: ...nge between 5 and 35 Isochronous fault 21 600 6 beats per second Date setting counter clockwise only Time setting Second hand stop function Normal position 1st click position Driving system Automatic...

Страница 2: ...Cal A and B Parts difference between Cal C and Cal D Parts code depends on type 53 Main plate 0104 164 0104 165 No Parts name 6R15C 6R15D 16 Oscillating weight with ball bearing 0509 400 1509 100 43 C...

Страница 3: ...ype of oil Oil quantity mark AO 3 Moebius A S 6 NORMAL QUANTITY S 4 SUFFICIENT QUANTITY 0012 354 Date dial guard screw 0808 183 Date dial maintaining plate Date dial 0810 183 Date jumper 3 18 Cal 6R15...

Страница 4: ...17 300 0836 183 Guard for date corrector setting transmission wheel 0802 183 Date indicator driving wheel 0962 185 Intermediate wheel for date setting C Cannon pinion Refer to the page 2 0962 023 for...

Страница 5: ...ance cock screw 0191 183 Automatic train bridge 0514 183 0171 354 Balance cock 0012 919 Ratchet wheel screw 0285 051 Ratchet wheel 0012 354 Pallet bridge screw 0161 300 Pallet bridge 0310 185 0301 009...

Страница 6: ...fer to page 12 for disassembling reassembling 0114 183 Barrel and train wheel bridge 0836 002 Reduction wheel holder 0436 166 Fourth wheel and pinion 0012 354 0231 070 Third wheel and pinion 0381 004...

Страница 7: ...e 0012 168 Setting lever jumper screw 0388 177 Setting lever jumper 0384 183 Yoke 0383 185 Setting lever 0601 183 Stop lever Refer to page 11 for oiling spot 0282 183 Clutch wheel 0283 020 Winding pin...

Страница 8: ...r Pallet fork Balance spring Third wheel pinion Escape wheel pinion Hole Jewel Cap Jewel Hole Jewel Cap Jewel Forth wheel pinion Center wheel pinion Name Cal 6R15C D 22 Balance cock screw 25 Pallet br...

Страница 9: ...Tools and consumables required for disassembling reassembling Movement holder UNIVERSAL MOVEMENT HOLDER S 682 Watch oils SEIKO Watch grease S 6 and S 4 Watch oil AO 3 or Moebius A S 6 AO 3 S 4 Cal 6R...

Страница 10: ...ide Note 2 After lubrication set lower plate for barrel and train wheel bridge screw Lower plate for barrel and train wheel bridge Lower plate for barrel and train wheel bridge screw 4 After lubricati...

Страница 11: ...fficiently Rotate the First reduction wheel manually until its hole aligns with the guide pin for Balance cock gilt dot and set the Oscillating weight vertically at the stem side and then tighten the...

Страница 12: ...Ratchet sliding wheel spring Sliding crown wheel spring Barrel and train wheel bridge 12 16 33 Disassembling Assembling Cal 6R15C D 31 29 Disassembling Assembling 30 29 Set the part to the Barrel and...

Страница 13: ...egulator Regulator pin Stud support Note Regulator Time adjustment Stud support Beat error adjustment Regulator pin Gap adjustment of balance spring and regulator pin 13 16 Anticlockwise rotation No c...

Страница 14: ...tor arm cock screw 3 Using sturdy tweezers push the stud outward 3 Temporarily set the stud to the stud support from the direction of the arrow shown in the Make sure that the balance spring passes ou...

Страница 15: ...lator and the balance spring passes parallel through the slot of the Regulator pin before fine tuning the STUD and the Regulator pin REGULATOR PIN 2 Rotate the STUD in order to align the position of t...

Страница 16: ...ccuracy of the watch is unimpaired 2 The date can be set by turning the crown counterclockwise Turn it until the previous day s date appears Ex If today is the 6th of the month first set the date to 5...

Страница 17: ...TER RESIST 10BAR 10 BAR WATER RESIST 15BAR 15 BAR WATER RESIST 20BAR 20 BAR SCUBA DIVERIS AIR DIVERIS 150 m 18 75 BAR 150 m times 0 125 SCUBA DIVERIS AIR DIVERIS 200 m 25 BAR 200 m times 0 125 He GAS...

Страница 18: ...ximately 41 hours until it stops 18 18 The parts of the watch may become magnetized depending on the extent of the effect In such a case consult the retailer from whom the watch was purchased since th...

Отзывы: