REMARKS ON REPAIRING CAL. 5J22A

Cal. 5J22A is an epoch-making model of SEIKO’s revolutionary KINETIC watches.  It is equipped with
innovative functions that have introduced a completely new concept into the KINETIC technology SEIKO has
cultivated in its long years of precision product manufacturing.  In repairing Cal. 5J22A, therefore, you are
requested to have the full knowledge of its functions and strictly observe the repairing and checking
instructions provided in this guide so that the watch will be repaired securely.

FEATURES OF CAL. 5J22A

Cal. 5J22A features the power save function that automatically stops the hands from moving if the watch is
left untouched for a certain period of time.  When you decide to use it again, swinging the watch several times
will activate the time relay function, which starts the hands moving quickly to indicate the correct time and
resume the normal operation.  In this way, Cal. 5J22A conserves the stored electrical energy by stopping the
hands while it is not in use, and, at the same time, it completely eliminates the cumbersome time setting
procedure when it is used again.

Thanks to this innovative mechanism, the duration of charge has increased enormously.

1.

POWER SAVE FUNCTION

·

While the watch is not in use, the hands stop automatically to minimize the electrical energy
consumed.  This is called “the power save function”.  Though the hands stop, the built-in IC continues
to compute the time, keeping the watch ready for the next use.

·

The power save function can be activated either automatically or manually.

The automatic power save function

·

If the watch is left untouched for approximately 72 hours, the power save function is automatically
activated.

The manual power save function

·

The power save function can be activated whenever you decide no to use the watch for a long time.

·

By pulling out the crown to the first click and pushing it in to the normal position within one second,
the power save function is activated manually.

Notes:

* Do not pull out the crown to the second click while the power save function is in operation.  Otherwise,

it is turned off, and the time retained inside the watch will be erased.

* While the second hand is moving at two-second intervals, the power save function cannot be activated

manually.

2.

TIME RELAY FUNCTION

·

While the power saving function is working, the built-in IC continues to compute the time though the
hands stop.  As the watch detects a certain amount of electricity generated by swinging it, the hands
are automatically adjusted to the time retained inside the watch, resuming the normal operation.  This
is called the “time relay function”.  As it is activated, the hour and minute hands are adjusted first, then,
followed by the second hand.

·

By only swinging the watch for 2 to 3 seconds, the time relay function will be activated.

Notes:

* The time relay function will not adjust the date.  If you find the date incorrect after it is activated, it is

necessary to adjust the date manually to the current date.

* The accuracy of the time computation by the built-in IC is equivalent to that of conventional quartz

watches.  If the power save function has been in operation for a long term before the time relay function
is activated, the time indicated by the hands may include a certain amount of time loss or gain that has
accumulated during that time.

3.

DURATION OF CHARGE

·

The duration of charge varies depending on the power reserve stored inside the watch.  If the watch
is fully charged, the power save function will keep it operating for about four years.

Note: If the power reserve is depleted completely while the power save function is in operation, the time

relay function may not be activated by swinging the watch.  Instead, the second hand starts moving
at two-second intervals.

Содержание 5J22A

Страница 1: ...tomatic power save function Manual power save function Time relay function Driving system Step motor Load compensated driving pulse type 2 pieces Loss gain Monthly rate at normal temperature range les...

Страница 2: ...you decide no to use the watch for a long time By pulling out the crown to the first click and pushing it in to the normal position within one second the power save function is activated manually Note...

Страница 3: ...t screw 1 pc 1 Hour minute and second hands 2 Dial 3 0012 354 Date dial guard screw 4 0353 558 Hour wheel guard spring 5 0808 557 Date dial guard 8 Date dial 7 0962 558 Second intermediate wheel for c...

Страница 4: ...clamp screw 17 4225 522 Rechargeable battery clamp 18 4216 524 Insulator for rechargeable battery 19 3023 24X Rechargeable battery unit 20 0012 354 Circuit block cover A screw 21 4457 771 Circuit blo...

Страница 5: ...nerating coil block 35 0317 557 Intermediate second wheel 36 0241 557 Fourth wheel and pinion 37 0231 557 Third wheel and pinion 38 4146 521 Second rotor 39 4146 521 Hour and minute rotor 40 0281 552...

Страница 6: ...0388 557 Setting lever spring 50 0383 557 Setting lever 51 0384 557 Yoke 52 0391 557 Train wheel setting lever 53 4239 524 Generating stator 54 4239 523 Second stator 55 4239 522 Hour and minute stato...

Страница 7: ...o SEIKO Casing Parts Catalogue to choose a corresponding date dial 56 Winding stem 0351 557 The type of winding stem is determined based on the design of cases Check the case number and refer to SEIKO...

Страница 8: ...e crown to the second click and turn it counterclockwise 2 Check if the date numeral moves in the calendar frame When it starts to move turn the crown slowly and stop turning it when the numeral stops...

Страница 9: ...heel in the direction as shown in the illustration at right Make sure that its longer pivot faces the movement side How to install 1 Apply the spring portion of the date driving wheel spring to the lo...

Страница 10: ...to the A portion gap in the illustration and pry up the rechargeable battery unit to remove it How to install Set the minus lead terminal to the guide post B in the illustration push C portion down ve...

Страница 11: ...ng rotor Note Be sure to observe the position type of oil and quantity of the lubrication specified in the illustration 28 Circuit block The portions indicated by the arrows in the illustration have e...

Страница 12: ...nd wheel They can be discriminated by the thickness of the pinions The third wheel and pinion has the thicker pinion 41 Intermediate minute wheel Case back side Main plate side Note Do not set the int...

Страница 13: ...d are made tight for the guide tubes to which they are set After setting the spacer for center wheel and pinion press down those portions so that it is well seated in position A portion B portion 48 S...

Страница 14: ...saving switch lead pin Do not remove the power saving switch lead pin except when necessary When installing the power saving switch lead pin press it in securely to the circuit block spacer Power savi...

Страница 15: ...for detecting generation Checking for leakage between coil for driving hands and coil for detecting generation If the hour and minute hands do not move properly when the time relay function is activa...

Страница 16: ...and a stable measurement can be obtained read the measurement If the measurement value remains high or unstable repeat step 3 above 1 Disassemble unnecessary parts to make the movement ready for the...

Страница 17: ...be switched from the quick start to the normal hand movement mode 3 Checking that a stable measurement is obtained read the current consumption Notes The current consumption measurement for the circui...

Страница 18: ...onserve the stored energy and the time relay function to start the hands moving to indicate the current time as the power save function is canceled For your information 1 Number of swings and power re...

Страница 19: ...al 5J22A which you will find helpful in working on the watch 1 The power save function is activated after the watch is left untouched for approximately 72 hours 2 The manual power save function is act...

Страница 20: ...Page 15 The current consump tion for the whole of the movement exceeds the standard value 1 After connecting the tester move the oscillating weight more quickly for a longer period of time and then ma...

Страница 21: ...ace the part if leakage is detected 1 There is electric leakage inside the hour and minute coil block After the time relay function is activated the hands do not make the quick movement smoothly or th...

Отзывы: