![Seiki SC-7500AU6A Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/seiki/sc-7500au6a/sc-7500au6a_installation-manual_1234458015.webp)
15
SELF DIAGNOSIS FUNCTIONS
The air-conditioner has sensors and a self diagnosis system which will display error codes
when an
issue is detected.
Self Check Information
Indicator Behaviour
Error Code Behaviour
Defrost Indication
1 flash per second
“dF” or a Heating icon
Room Temperature Sensor
Fault
1 flash per second
E2
Coil Temperature Sensor
1 flash per 8 seconds
E3
External Feedback Fault
7 flashes per 8 seconds
E7
Outdoor Tube Temperature
Sensor Faults
4 flashes per 8 seconds
E1
(EEPROM) Communication
failures
6 flashes per 8 seconds
E6
Outside Temperature
exceeds operational range
1
flash per second
FF
Содержание SC-7500AU6A
Страница 2: ......
Страница 17: ...17...
Страница 18: ...18...
Страница 19: ...19...
Страница 20: ...CUSTOMER HELPLINE 1300 296 699 DISTRIBUTED BY AYONZ PTY LTD...