Seiki SC-115AU6BFW Скачать руководство пользователя страница 4

4

Read this manual thoroughly before you start using the 115L Bar Refrigerator.

The safety precautions instructions reduces the risk of fire, electric shock and injury when 

correctly complied to. 

Please follow all instructions and take notice of all warnings.

The refrigerant isobutane (R600a) is contained within the refrigerant circuit of 

the appliance, a gas with a high level of environmental compatibility, which is 

flammable. During transportation and installation of the appliance, make sure that 

none of the components of the refrigerant circuit become damaged.

WARNING: 

Never use an appliance with a damaged refrigerant circuit. If the 

refrigerant circuit becomes damaged, avoid proximity to open fires and all types  

of heat and ignition sources. Thoroughly ventilate the room in which the appliance 

is located.

It is dangerous for anyone other than an authorised service person to work on this

appliance. In Queensland, the authorised service person 

MUST

 hold a Gas Work

Authorisation for hydrocarbon refrigerants to carry out servicing or repairs which

involve the removal of covers.

The room for installing the appliance must be at least 1m3 per 8g of refrigerant.

The amount and type of refrigerant in the appliance can be found in the Technical

Specifications at the back of the manual and on the appliance rating label.

Pay close attention to messages that follow this safety alert symbol 

or the words 

DANGER

WARNING

 or 

CAUTION

. These words will be 

used to alert you of potential hazards that and injure you and others. 

Following these instruction will tell you how to reduce the chance of 

injury and the possible dangers if instructions aren’t followed.

This symbol alerts you to take care as the appliance contains 

flammable materials: isobutane as refrigerant and cyclopentane as 

insulation blowing gas. Do not expose it to high heat, sparks and 

open flames.

IMPORTANT INFORMATION

GENERAL SAFETY

Содержание SC-115AU6BFW

Страница 1: ...115L BAR REFRIGERATOR INSTRUCTION MANUAL MODEL SC 115AU6BFW Please read this manual carefully before using and keep it for future reference...

Страница 2: ......

Страница 3: ...General Safety 4 Product Overview 7 Installation 8 Operation 9 Changing the Light Bulb 9 Reversing the Door 10 Troubleshooting 11 Speci cations 12 Customer Helpline 12 CONTENTS...

Страница 4: ...an authorised service person to work on this appliance In Queensland the authorised service person MUST hold a Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs whi...

Страница 5: ...SAFETY Voltage Plug the appliance to a 220 240V 50Hz properly earthed power outlet it must be in good working order Power connection Do not use an adaptor or an extension cord Plug the power plug dir...

Страница 6: ...mpt to alter or modify this appliance Intended purpose Do not use any electrical or electronic appliances inside the food storage compartments of the appliance unless they are of the type recommended...

Страница 7: ...RVIEW 1 Cabinet 2 Cool Zone Compartment 3 Drip Tray 4 Shelf 5 Glass Cover 6 Compressor back 7 Crisper Box 8 Levelling Legs 9 Bottle Racks 10 Recessed Handle 11 Door Switch 12 Temperature Control Knob...

Страница 8: ...Allow 10cm clear space between the back and sides of the appliance and your wall or anything else to make sure there is enough air circulation which is needed to allow for the cooling of the compress...

Страница 9: ...is the most general option for refrigerators The higher the number the cooler the temperature Changing the internal lightbulb is only to be done by approved Service Agents 1 Hold the lamp cover and p...

Страница 10: ...and then remove the hinges 2 5 Remove the left front leg 4 and transfer it to the right side 6 Remove the hole cover plate 7 to the right side 7 Before placing this lower hinge 2 remove the bolt pin...

Страница 11: ...e refrigerant which is standard You may hear gurgling sounds caused by the ow of refrigerant Contraction and expansion of the internal walls may cause popping and crackling noises The door will not cl...

Страница 12: ...Storage Volume 92 Litres Evaporator Compartment Vol ume 14L Climate Class T Power Supply 220 240V 50Hz Rated Power of Lamp 10W Refrigerant R600a 30g Insulation Blowing Gas Cyclopentane CUSTOMER HELPLI...

Отзывы: