Version No. 1-12 - 24.01.2022

Doc. No. 99872500201USL

16 / 21

Failure

Code

Description

Solution

E07 / E08

Controller error

Contact your service partner.

 

Important Notes:

Whilst programming, if no button is pressed for 10 seconds, the display starts flashing, and after 1 minute
returns to the main display without saving changes.
To increase scrolling speed, press and hold the ▲ or ▼ button for at least 5 seconds.
When pressing “PRG” for 3 seconds, the firmware revision code is displayed for 2 seconds.
When cleaning the controller panel, do not use ethanol, hydrocarbons, ammonia or their by-products. 
Use neutral detergents and water.
In order to protect the unit’s components, minimum relay output on (3 or 7 minutes) and off (4 minutes)
times and minimum time (7 or 11 minutes) between activation of the same relay output are applied.
In case of digital inputs not configured, probes not fitted or configured, or St2 not enabled on the
controller the display shows ‘nO’.

Содержание 872500201USL

Страница 1: ...ions 4 4 Settings 5 5 Functional principle 6 6 Technical data 7 7 Mounting 8 8 Condensate management 9 9 Mounting Principle 10 10 Electrical Connection 11 11 Controller 13 12 Wiring Diagram 17 13 Taki...

Страница 2: ...dissipation of heat from control cabinets and enclosures stationary not moving in order to protect temperature sensitive components in an industrial environment To meet the conditions of use all the...

Страница 3: ...d units based on the information diagrams or descriptions contained in this manual No liability can be accepted for damage and production caused by Disregarding the instruction manual Operating error...

Страница 4: ...ety regulations One can nd dangerous voltages above 50 V AC or above 100 V DC Behind the control cabinet doors On the power supply in the unit housing The unit has to be operated according to the type...

Страница 5: ...r does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclosure...

Страница 6: ...ant thus taking it to high pressure and high temperature and pushes it through the condenser where it is cooled by ambient air thus passing from the gas to the liquid state At the liquid state it then...

Страница 7: ...880 m h Schrankkreislauf 610 880 m h Mounting Wall mounted Housing Material Mild steel powder coated Dimensions A x B x C D E 890 x 395 x 305 mm Weight 47 kg Voltage Frequency 230 V 50 60 Hz UL Voltag...

Страница 8: ...e cut packaging opening facing up STEP 2 Pull o the packaging opening STEP 3 Hang the transport loop of the unit in the transport hook and lift it slightly STEP 4 Pull o the packaging and slide out th...

Страница 9: ...the holes and make the required cuts on the enclosure This template may have been a ected by storage conditions please check this template by verifying values of the largest dimensions before drillin...

Страница 10: ...within the rst 15 minutes after installation Use only the supplied mounting hardware Tighten Screws to 4 5 Nm Ensure the mounting surface does not warp after assembly and reinforce it if necessary 1...

Страница 11: ...if closed Door contact terminals bridged or NC door switch connected contact must be closed when cabinet door is closed c68 1 ON if open Remove bridge or NO door switch connected contact must be open...

Страница 12: ...2022 Doc No 99872500201USL 12 21 SCCR Refer to UL508A Supplement SB and Seifert Systems document Short Circuit Current Rating SCCR on methods how to modify the available short circuit current within a...

Страница 13: ...gress 2 Alarm relay active 3 Heater relay active 4 Ambient blower relay active Alarm Flashes when alarms are active Heating mode Signals operation of unit in heating mode Cooling mode Signals operatio...

Страница 14: ...re C 0 F 1 P25 for low temperature alarm threshold default 10 C 14 F P26 for high temperature alarm threshold default 55 C 131 F c68 for door contact NO NC logic change 0 ON if closed 1 ON if open Con...

Страница 15: ...with an icon ashing triangle alternating with the standard display If more than one error occurs these are shown in sequence on the display Failure Code Description Solution OFF Door open Close the e...

Страница 16: ...button for at least 5 seconds When pressing PRG for 3 seconds the rmware revision code is displayed for 2 seconds When cleaning the controller panel do not use ethanol hydrocarbons ammonia or their b...

Страница 17: ...Version No 1 12 24 01 2022 Doc No 99872500201USL 17 21 12 Wiring Diagram Power connector 1 L1 2 3 N 4 PE Signal connector 1 Alarm NC 2 Alarm COM 3 Alarm NO 4 Door contact 5 Door contact...

Страница 18: ...ssor don t work Enclosure temperature is below setting temperature St Verify values of parameter St Door switch contact is open Verify door switch Controller doesn t work Replace controller Internal f...

Страница 19: ...ld be replaced immediately Do not use a steam jet or high pressure to clean the lter mats Do not wring out the lter mats If the ambient air is extremely oily we recommend the use of metal lters see ac...

Страница 20: ...ons temperature range 40 C to 70 C relative humidity at 25 C max 95 the cooling unit should always be stored according to the installation position Returning the unit To avoid transport damage the uni...

Страница 21: ...Version No 1 12 24 01 2022 Doc No 99872500201USL 21 21 17 Parts supplied Spare parts Accessories 75 Circuit Drive North Kingstown RI 02852 United States Tel 401 294 6960...

Отзывы: