Seifert 752501B001 Скачать руководство пользователя страница 1

Version Nr. 1-3 - 09.11.2022

Doc. No. 99752501B001

1 / 17

Table of Content 752501B001

1. User manual 

2

 .................................................................................................................................. 

2. Legal regulations 

2

 ......................................................................................................................... 

3. Safety instructions 

3

 ...................................................................................................................... 

4. Settings 

4

 ......................................................................................................................................... 

5. Functional principle 

5

 ..................................................................................................................... 

6. Technical data 

6

 .............................................................................................................................. 

7. Performance graph 

7

 ...................................................................................................................... 

8. Mounting 

8

 ....................................................................................................................................... 

9. Mounting Principle 

9

 ....................................................................................................................... 

10. Cut out dimensions 

10

 .................................................................................................................. 

11. Dimensions (H x W x D) 

11

 .......................................................................................................... 

12. Controller 

12

 .................................................................................................................................. 

13. Wiring diagram 

13

 ......................................................................................................................... 

14. Taking into operation 

14

 .............................................................................................................. 

15. Maintenance & Cleaning 

15

 ......................................................................................................... 

16. Maintenance 

15

 ............................................................................................................................. 

17. Transport & Storage 

16

 ................................................................................................................ 

 

Содержание 752501B001

Страница 1: ...fety instructions 3 4 Settings 4 5 Functional principle 5 6 Technical data 6 7 Performance graph 7 8 Mounting 8 9 Mounting Principle 9 10 Cut out dimensions 10 11 Dimensions H x W x D 11 12 Controller...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates e...

Страница 3: ...ad with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid sa...

Страница 4: ...t be soft enough to avoid scale deposits but should not be too soft as this would corrode the heat exchanger Where the cooling water is cooled for reuse part of the water has to be changed with fresh...

Страница 5: ...s circulation of the air in the cabinet This circulation prevents hot spots within the control cabinet During this process the coolant heats up and is returned to the coolant supply system at an incre...

Страница 6: ...terial Mild steel powder coated Dimension H x W x D 1 350 x 395 x 192 37 155 mm Weight 29 kg Voltage Frequency 230 V 50 60 Hz Starting current 0 6 0 7 A Max current 0 5 0 6 A Max power 105 125 W Press...

Страница 7: ...Version Nr 1 3 09 11 2022 Doc No 99752501B001 7 17 7 Performance graph...

Страница 8: ...sealed control cabinet will result in an increased level of condensation The control cabinet should have a minimum of IP54 protection in accordance with IEC 60 529 Cooling medium connection There are...

Страница 9: ...Version Nr 1 3 09 11 2022 Doc No 99752501B001 9 17 9 Mounting Principle...

Страница 10: ...Version Nr 1 3 09 11 2022 Doc No 99752501B001 10 17 10 Cut out dimensions...

Страница 11: ...Version Nr 1 3 09 11 2022 Doc No 99752501B001 11 17 11 Dimensions H x W x D...

Страница 12: ...e gesch tzten Parameter Sobald Sie auf die Parameterliste zugreifen wird wieder PS angezeigt Dr cken Sie die Tasten UP oder DOWN um durch die verschiedenen Parameter zu bl ttern Dr cken Sie SET um bei...

Страница 13: ...Version Nr 1 3 09 11 2022 Doc No 99752501B001 13 17 13 Wiring diagram Zuleitung PE N L1 Signalsteckverbinder T rkontakt T2 T rkontakt T1 Alarmkontakt P2 Alarmkontakt P1...

Страница 14: ...s to scroll the numbers until displaying 22 default password to access the parameters press the SET button to con rm the password 3 Use the UP and DOWN buttons to scroll the parameters The LED corresp...

Страница 15: ...fan by loosening the 4 fastening screws To detach the fan from the fan support loosen a further 4 screws and the fan connecting cable When connecting the new fan take care that the correct polarity is...

Страница 16: ...to the unit through incorrect transport Please ensure that all liquid has been removed prior any transport To avoid transport damage the unit should be returned in the original packing or in a packin...

Страница 17: ...state North Kingstown Wantirna South 42477 Radevormwald Birzebbuga BBG 3000 4563 Gerla ngen 4901 Ottnang 26100 Cremona RI 02852 3152 Victoria Germany Malta Switzerland Austria Italy USA Australia Tel...

Отзывы: