− 35 −
② DLP COLOR TEST
Select DLP COLOR TEST to display the adjustment screen for the main unit monitors
(projectors).
On selection of DLP COLOR TEST, the entire screen is displayed white.
Press the TEST Button to display white-to-black gradation on the entire screen.
Press the TEST Button again to return to the Main Test Menu screen.
Adjust so that the colors of the left and right projectors are the same.
Read the Owner's Manual Section 14 for details of the adjustment procedure.
③ SYNCHRONOUS TEST
The SYNCHRONOUS TEST enables checking of the synchronization of the main unit monitors
(projectors).
This test requires both sides to be in test mode. Operation is normal if the "CHECKING"
indication is followed by "SYNCHRONOUS OK."
The following describe sources of error indication.
For the following error indications, check for any disconnection of serial cables linking to the
NAOMI 2 board inside the main unit or other connection faults.
● "SERIAL COMMUNICATION ERROR"
Serial cable disconnection or other connection faults are likely causes.
● "SYNCHRONOUS ERROR"
Serial cable disconnection, a board problem or a chip problem are likely causes.
<<SYNCHRONOUSTEST>>
SYNCHRONOUSOK
PRESSTESTBUTTONTOEXIT
FIG. 2. 5 c SYNCHRONOUS TEST screen
After changing the settings, select EXIT and press the TEST Button to return to the Main Test
Menu screen.