Dismantling / Reassembly
9.1
Pump Dismantling/Reassembly
Range: BTQ
Size: 05-24 to 70-6L
9.1.1 Preparing the pump for dismantling
9.1.2 Dismantling
9.1.2.1 Pressure branch (700) - Dismantling
DANGER
Dangerous voltage.
Death or serious injury can occur.
Note safety regulations.
Disconnect motor from all sources of energy.
Secure electrical connections against restarting.
Empty the pipelines.
Allow pipelines to cool.
Remove the connections to the pipelines
(FLA)
and the extension hopper
(AST)
(suction side/pressure side).
Observe de-commissioning instructions
(
chapter 6.4).
WARNING
Risk of pump tipping or falling.
Death or serious injury can occur.
Fasten the lantern
(200)
to secure the
pump.
Prop up stator
(601)
with a support
(S)
.
Remove screw fitting
(604, 606)
.
Remove pressure branch
(700)
.
Remove tie bolt
(602)
.
Содержание BTQ Series
Страница 2: ......
Страница 6: ...Index Index Index Index Subsidiaries Subsidiaries Subsidiaries Subsidiaries ...
Страница 16: ...10 ...
Страница 18: ...12 ...
Страница 24: ...18 ...
Страница 44: ...38 ...
Страница 48: ...42 ...
Страница 49: ... Ausgabe issue B 29 03 2011 Dokument document OM SZG 02e Blatt sheet 1 1 10 Spare parts 10 1 Spare parts list ...
Страница 50: ...44 ...
Страница 54: ...48 ...
Страница 56: ...50 ...
Страница 58: ...52 ...
Страница 59: ...53 ...