PRE-SEASON SERVICE
WARNING: Do not run the air cooler with
the pad frames removed.
REMOVAL OF PAD FRAMES
•Turn off the power supply to the air cooler
•Remove the pad frames as shown.
•Ensure the power switch in the cooler is off.
•Gently wash the pads to remove any dust
build up during the winter period. If the pads
are in poor condition, replace them.
IMPORTANT: Do not damage the pads with
high pressure water spray.
•Replace the bleed system if it was removed
during previous maintenance and ensure the
o-ring is fitted. (If the cooler is fitted with a
drain valve this will not be necessary as it will
automatically close when the cooler turns
on).
•Turn on the power switch inside the cooler.
•Turn on the water and then the power.
•Re-fit the pad frames and run the cooler.
To remove a pad frame, insert a flat screw
driver tip into the slot as shown and lever until
disengagement occurs.
Take hold of the pad frame and pull it towards
you until the internal side clips disengage.
Pivot the pad frame outwards and lift up. Take
care not to damage the pad. Repeat these
steps for the remaining pad frames.
TROUBLESHOOTING GUIDE
PROBLEM – Inadequate Cooling
CAUSE
ACTION
1.
Pump not working correctly
Check plug, wiring and circuit breaker.
Impellor may be jammed or obstructed.
Check salinity sensor correctly installed Rectify fault or
replace pump.
2.
Dry pads.
Check water flow to pads.
Inspect fitment of distributor cap.
Check for blocked or kinked hose. If blocked, dismantle,
clean and flush or unkink the hose.
3.
Leaking ducts
Find leaks and seal.
PROBLEM – Unpleasant Odour
PROBLEM – Wall Control flashes “SERVICE”
CAUSE
CAUSE
ACTION
ACTION
1.
Odour from new pads.
1.
An operational fault has been
detected
Allow time to condition by running the air cooler
Ensure the water supply is turned ON
Check the cooler drain pipe is not blocked.
Turn OFF the Wall Control and record the number
displayed on the screen. Quote this number to your
Service Agent.
If your wall control display flashes “Service” or should you consider that your air cooler requires
service, you should contact your local Dealer.
When you contact your Dealer regarding service or warranty please quote the unit model number
and serial number as shown below.
Model No.................................
Serial No.....................................
10
SEELEY INTERNATIONAL –
OWNER’S MANUAL
11
MAINTENANCE
®
TBA Evaporative Cooler
Содержание TBA250
Страница 2: ......
Страница 74: ...16 ILL1135 B 2 x 5 0mm Plasterboard or 2 x 6 0mm Brick 72 TBA Evaporative Cooler ...
Страница 75: ......