BMS INDUSTRIAL CONTROLLER M1

BMS INDUSTRIAL CONTROLLER MS1

ILL2470-A

1

MaglQtouch Industrial Controller MS1

2

1

Installation and Operation Manual

3

2

Wall Brackets

4

2

Wall Plug Yellow 5mm

5

2

Screw PAN PHIL 6ABX1” ZNP

6

ILL2471-A

1

3m Communications Cable

ILL2109-A

SI

G

GND

ERROR

ST

A

T

US

OUTPUT

COOL INPUT

ACTUAL 

F

AN

SPEED

OUTPUT

SIG

GND

SI

G

GND

SYSTEM

ON INPUT

SET 

F

A

N

SPEED

INPUT

PWR /

ERROR CODE

SI

G

GND

SI

G

GND

+12VDC

0VD

C

POWER

INPUT

BMS INDUSTRIAL CONTROLLER M1

BMS INDUSTRIAL CON

TROLLER MS1

ILL2470-A

INSTALLATION & 

OPERATION MANUAL

MagIQtouch BMS Industrial Controller MS1

(Coolers Only)

Original English Instructions

(English) (Industrial Controller M1) 

BMS INDUSTRIAL CONTROLLER M1

BMS INDUSTRIAL CONTROLLER MS1

TM

Содержание MAGICTOUCH MS1

Страница 1: ...UT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2470 A INSTALLATION OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 Coolers Only Original English Instructions English Industrial Controller MS1 ...

Страница 2: ...i ...

Страница 3: ...ount 7 ELECTRICAL INSTALLATION 8 Typical Installation Options 8 Master Mode Single Cooler 8 Master Mode Multi Coolers 8 Slave Mode Single Cooler Option 1 9 Slave Mode Single Cooler Option 2 9 Slave Mode Multiple Coolers Option 1 10 Slave Mode Multiple Coolers Option 2 10 Master Or Slave Mode 11 Master Mode 11 Slave Mode 11 Activating Master Or Slave Mode 11 Connecting Cooler or Wall Control to BMS...

Страница 4: ...l 3 2 Wall Brackets 4 2 Wall Plug Yellow 5mm 5 2 Screw PAN PHIL 6ABX1 ZNP 6 ILL2471 A 1 3m Communications Cable ILL2109 A SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2470 A INSTALLATION OPERATION MANUAL MagIQtouch...

Страница 5: ...nt happening What could the possible consequence be What can you do to reduce or better still completely get rid of the risk WARNING The MagIQtouch BMS Controller requires an approved Safety Extra Low Voltage SELV 12Vdc power supply to be connected to the power supply input of the MagIQtouch BMS controller The outputs from the controller require this approved SELV power supply in order to maintain...

Страница 6: ...nnected from the power source when installing the MagIQtouch BMS Industrial Controller select and prepare an appropriate mounting site with the following features Space for mounting on either DIN rail or directly to the wall Clearance for inserting digital analogue inputs outputs Within 100m of cooler Dedicated 12Vdc power input for Actual fan speed and logic Error Status signal Note Do not use po...

Страница 7: ...cturer s warranty 100m 328 MAX Seeley International cooler SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2472 A MASTER MODE Maximum cable length SLAVE MODE Maximum cable length Seeley International cooler SIG GND ER...

Страница 8: ...ouch Industrial Wall Controller cable ferrite 864402 40m 131 MagIQtouch Industrial Wall Controller cable ferrite 834238 60m 197 MagIQtouch Industrial Wall Controller cable No ferrite 834474 500m 1640 Roll of 6 core ribbon cable with no terminations or plugs Plug Type 6 pin Farnell 781 289 wired as below 670423 Hinged Bracket Ferrite BLUE YELLOW GREEN RED BLACK WHITE ILL2123 A COMMUNICATION CABLE c...

Страница 9: ...MS MS1 is suitable for internal installations only Within the MagIQtouch BMS Industrial Controller kit are 2 x wall brackets push fit them into the each side of the enclosure base Mark and drill suitable holes in wall and insert wall plugs provided Align and screw the MagIQtouch BMS Industrial Controller on to the wall ILL2103 A ILL2104 A SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUT...

Страница 10: ...S1 Master per 1 x cooler MASTER MODE MULTI COOLERS NOTE 1 x BMS MS1 Master per 1 x cooler EVAP COOLER 3 EVAP COOLER 2 EVAP COOLER 1 CUSTOMER BMS 100m SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 SIG GND ERROR STATUS O...

Страница 11: ...ND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2476 B ILL2476 B EVAP COOLER 1 CUSTOMER BMS 20m BMS MS1 SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRI...

Страница 12: ...10 ELECTRICAL INSTALLATION cont SLAVE MODE Multiple Coolers Option 1 With link modules SLAVE MODE Multiple Coolers Option 2 With Dual RJ socket on Cooler electronics ILL2478 B ILL2479 C ...

Страница 13: ...ration Slave Mode The BMS MS1 controller is a Slave to the MagIQtouch wall controller When the BMS MS1 ON OFF signal is ON the BMS MS1 controller takes control of the MagIQtouch wall control remotely During remote access the MagIQtouch wall control will display BMS CONTROL and will not be operational Activating Master or Slave Mode Remove the front cover of the BMS MS1 controller and set the dip s...

Страница 14: ...12 ELECTRICAL INSTALLATION cont CONNECTING COOLER OR WALL CONTROL TO BMS MS1 ILL2481 A ILL2481 A ...

Страница 15: ...e Label Function Low High Input Type On Off SYSTEM ON INPUT Master mode only Turn Cooler On or Off Cooler Off Cooler On Digital 10Vdc Slave mode only Switch operation between Wall control and BMS MagIQtouch Control BMS Control Digital 10Vdc Operation Mode COOL INPUT Cool or Vent Fan Only Cool Mode Digital 10Vdc Fan Speed SET FAN SPEED INPUT Set speed from 1 10 N A N A Analogue 0 10Vdc Logical Leve...

Страница 16: ...0 0 0 1 2 8 2 2 2 3 6 2 8 3 4 4 3 6 4 5 2 4 4 5 6 0 5 2 6 6 7 6 0 7 7 5 6 8 8 8 2 7 5 9 9 0 8 3 10 10 0 Optional 12Vdc power input POWER IN 12VDC Power input only required if ACT FAN SPEED and ERROR STATUS signals are required from the module If Power input is not connected ERROR STATUS and ACT FAN SPEED will not work Min Typ Max Unit Voltage DC 11 5 12 12 5 V ...

Страница 17: ...ROR ERROR PULL UP RESISTOR BMS DC POWER RAIL V BMS 0V BMS MS1 MODULE Monitor Voltage V No Error V Error ERROR ERROR BMS DC POWER RAIL V BMS 0V BMS MS1 MODULE Contact open No Error Contact closed Error Normally Open contacts1 RELAY COIL ILL2484 B POWER IN 12V ERROR ERROR R18 RXE005 D3 ISMA4753 POWER IN 0V R22 470R R15 4K7 3 1 2 C E B Q1 BC640 ILL2483 B OUTPUT SIGNALS ERROR STATUS ILL2483 B The diag...

Страница 18: ...ng on the precision of the POWER IN 12V supply ELECTRICAL INSTALLATION cont Actual Fan Speed VOUT min VOUT typ VOUT max 0 0 0 0 8 1 0 1 1 0 1 3 1 6 2 1 7 2 2 2 5 3 2 7 3 2 3 5 4 3 7 4 2 4 5 5 4 7 5 2 5 5 6 5 7 6 2 6 5 7 6 8 7 2 7 5 8 7 8 8 2 8 6 9 8 8 9 3 9 6 10 9 8 10 3 12 0 ...

Страница 19: ...g on the front panel The type of error will be indicated by the sequence of flashes highlighted on ERROR CODE LED Errors can be cleared by applying a low level and then high level on the SYSTEM ON INPUT Error codes can be cleared using the RESET button on the front of the controller OFF BMS Module Off no power received from Cooler on RJ port ON BMS is operational Communication to Cooler and Wall C...

Страница 20: ...18 CONNECTION DIAGRAM ILL2512 B ...

Страница 21: ...tch position Cycle power to Cooler Cable not connected correctly Refit cable Cycle power to cooler Cable damaged or broken Replace cable Cycle power to cooler The PWR LED is flashing multiple flashes sequence The cooler has a fault Refer to cooler manual to solve the fault on the cooler Cycle power to cooler The PWR LED is illuminated but the Cooler is not starting The ON input is not set to High ...

Страница 22: ......

Страница 23: ......

Страница 24: ... the specifications of the model selected MANUFACTURED BY Seeley International Pty Ltd 112 O Sullivan Beach Road Lonsdale SA 5160 Australia for Australia USA Europe and South Africa IMPORTED BY Seeley International Americas Ltd 1002 S 56th Avenue Suite 101 Phoenix Arizona 85043 USA Seeley International Europe Limited Unit 11 Byron Business Centre Duke Street Hucknall Nottingham NG15 7HP United Kin...

Отзывы: