List of Abbreviation 

 

This list contains the list of acronyms used in this document and it can be used to refer their respective 
description. This List Does not contain units of measure. 
 

Acronym 

Description 

AC 

Alternating Current 

ACK 

Acknowledge 

ALT 

Alternator 

AMF 

Auto Mains Failure 

AUX 

Auxiliary 

BTS 

Base Transceiver Station 

CHG 

Charging 

CKT 

Circuit 

CT Ratio 

Current Transformer Ratio 

DC 

Direct Current 

DG 

Diesel Generator 

DIG IN 

Digital Input 

ENG TEMP 

Engine Temperature 

GCU 

Genset Control Unit 

Genset 

Generator Set 

GND 

Ground 

HMI 

Human Machine Interface 

HSD 

High Side Driver 

HWT 

High Water Temperature 

LCD 

Liquid Crystal Display 

LED 

Light Emitting Diode 

LLOP 

Low Lube Oil Pressure 

LOP 

Lube Oil Pressure 

LVL 

Level 

MCP 

Manual Control Panel 

MPU 

Magnetic Pickup Unit 

OV 

Over Voltage 

PID 

Proportional Integral Derivative 

PWM 

Pulse Width Modulation 

RMS 

Root Mean Square 

RPM 

Revolutions Per Minute 

R-Y-B 

Red-Yellow-Blue 

SCP 

Sensor Common Point 

SMD 

State Machine Diagram 

TEMP 

Temperature 

USB 

Universal Serial Bus 

UV 

Under Voltage 

 

 

 

Содержание CB12XX SERIES

Страница 1: ...CB12XX SERIES BATTERY CHARGERS Product Manual Version 1 00 ABSTRACT This manual is intended as an Information guide for operating SEDEMAC s CB12XX series battery chargers Doc SED MAN CB12XX 002 Date 1...

Страница 2: ...owned by their respective companies SEDEMAC Mechatronics Pvt Ltd reserves the right to change the contents of this document without prior notice For permission requests and applications to reproduce...

Страница 3: ...ctice which could result in injuring personnel or loss of life if not followed correctly Electrical safety Electric shock can cause severe personal injury or death Ensure the generator set must be gro...

Страница 4: ...or wires while standing in water while barefoot or while hands or feet are wet IT MAY RESULT IN SEVERE ELECTRICAL SHOCK Do not wear jewellery Jewellery can cause a short circuit within electrical cont...

Страница 5: ...e AUX Auxiliary BTS Base Transceiver Station CHG Charging CKT Circuit CT Ratio Current Transformer Ratio DC Direct Current DG Diesel Generator DIG IN Digital Input ENG TEMP Engine Temperature GCU Gens...

Страница 6: ...when it is printed Page 4 of 19 Table of Contents 1 Introduction 7 1 1 Key Highlights of the Product 7 1 2 Product Variants 7 2 Charging Principle 7 3 Modes of Operation 8 4 Installation 8 4 1 Pin Te...

Страница 7: ...re 1 Charging characteristics graph 7 Figure 2 Pin terminals of CB12XX 8 Figure 3 CB1205 Front View 10 Figure 4 CB1205 Side view 10 Figure 5 CB1205 Top view 10 Figure 6 CB1210 front view 11 Figure 7 C...

Страница 8: ...nyone without the written permission of the company This document is controlled when it is printed Page 6 of 19 List of Tables Table 1 Mounting Information parameters for CB1205 and CB1210 9 Table 2 M...

Страница 9: ...1 1 Key Highlights of the Product Automated three stage battery charging features is provided to ensure longer battery life Advanced switch mode supply design is responsible for higher output efficie...

Страница 10: ...tage needs to be constant at optimum value To achieve this the battery is charged continuously The float charge thus compensates any loss caused by self discharge and keeps the battery fully charged 3...

Страница 11: ...AC mains In order to operate the charger in manual boost mode short the terminals of Boost select by means of a wire The recommended torque while tightening screws at the connecting terminals is 0 4...

Страница 12: ...Mechatronics Pvt Ltd It shall not be communicated to or copied by anyone without the written permission of the company This document is controlled when it is printed Page 10 of 19 4 3 2 CB1205 Case Di...

Страница 13: ...Mechatronics Pvt Ltd It shall not be communicated to or copied by anyone without the written permission of the company This document is controlled when it is printed Page 11 of 19 4 3 3 CB1210 Case Di...

Страница 14: ...Ltd It shall not be communicated to or copied by anyone without the written permission of the company This document is controlled when it is printed Page 12 of 19 4 4 Mounting on Panel Figure 9 Mount...

Страница 15: ...ecifications and parameters for CB12XX Bulletins Contents Parameters CB1205 CB1210 Input Characteristics Nominal input AC voltage range 110V AC to 290V AC 110V AC to 290V AC Max input AC voltage range...

Страница 16: ...all not be communicated to or copied by anyone without the written permission of the company This document is controlled when it is printed Page 14 of 19 6 Efficiency Curve Figure 11 Efficiency Curve...

Страница 17: ...hing between Blue and Green LEDs Battery charger s output short circuit Check the output terminal connections 2 Red led Rightmost is ON Reverse connection of battery charger output with battery BAT co...

Страница 18: ...ev 01 NOTE This document is a property of SEDEMAC Mechatronics Pvt Ltd It shall not be communicated to or copied by anyone without the written permission of the company This document is controlled whe...

Страница 19: ...when it is printed Page 17 of 19 Disclaimer Due to continuous development the details provided in this document are subject to change without any prior notice SEDEMAC Mechatronics Pvt Ltd Technical C...

Отзывы: