A)

 Press the number “8” on the phone to extend the time intervals for an additional 20 seconds to enter the listening 

state. In the listening  state the built-in microphone on the alarm host will be active to pick up any sound that takes place 
near by the alarm host. 

b)

 Press the pound “#” button to replay the recorded voice message.

C)

 Press the star “*” button, the host will end/drop the call and stop to dial the next enlisted alarm telephone numbers.  

After the “*“ is pressed; the alarm host will resume to be armed.

note: The “*” is required in order to stop the alarm host from continuing to dial the next enlisted telephone numbers.

D)

 Hang up the telephone without any command input, the host will end the call and automatically continues to dial the 

next enlisted alarm telephone numbers.

remote arm by phone:

 30 seconds after successfully dialing the telephone number of alarm host, there will be: a beep > enter 

programming password of host > beep > enter 1 > beep, and the host will then automatically hang up after the last beep to 
successfully complete the operation. 

remote disarm by phone: 

30 seconds after successfully dialing the telephone number of alarm host, there will be: a beep > 

enter programming password of host > beep > enter 0 > beep, and the host will then automatically hang up after last beep to 
successfully complete the operation.

Alarm dialing mode: 

After the alarm host triggered or gone off, the alarm host will start to dial the first enlisted telephone 

number, then the second, third, fourth and so on. Unless one of the enlisted telephone numbers answers otherwise this routine 
auto dial will continue through a series of loop for three times. 

Alarm priority: 

If the telephone line is busy or in use when the alarm host is triggered, the alarm host will automatically cut off 

the busy/used line and dial the enlisted telephone numbers to advise of the crime. The system will siren and then dial out to 
the enlisted telephone numbers is the alarm’s top priority.

Telephone line disconnection Alarm: 

If the telephone line is cut or comes off the hook, the host will beep every 5 seconds to 

notify users that the telephone line is not connected to the TEL IN port of the alarm host unit or it is connected to the alarm 
host but it is not an active telephone line. It will continue to beep until the phone line is fixed or reconnected. 

“AWAY” Mode (Zone 1~15):

 In this state, after any detection in the 1st, 2nd, or 24hr defense line is triggered, the alarm host will 

immediately sound the sirens and at the same time automatically dial the enlisted telephone numbers in sequence. 

“HOMe” Mode (Zone 1~10):

 In this state, after any detection in the 1st or 24hr defense line is triggered, the alarm host will 

immediately sound the sirens and at the same time automatically dial the enlisted telephone numbers in sequence. In HOME 
mode, the 2nd defense line will be disabled and will not trigger the alarm host.  

7

Содержание AIR-ALARM II SERIES

Страница 1: ...AIR ALARMII SERIES USER s MANUAL D I Y Wireless SMART HOME ALARM SYSTEM KIT...

Страница 2: ...class B digital equipment in Part 15 of FCC regulation The product generates applies and emits radio waves It might cause harmful interferences to wireless communication if not be installed and used f...

Страница 3: ...f SecurityMan Inc arising from this warranty and sale shall be limited to a refund of the purchase price In no event shall SecurityMan be liable for costs of procurement of substitute products or serv...

Страница 4: ...ireless Accessories Wireless Remote Controllers SM 88X Wireless Smart Door Window Sensor SM 87L Wireless Doorbell Button SM 82 Wireless Wide Angle PIR Motion Sensor SM 80 Wireless Indoor Siren SM 103W...

Страница 5: ...e system will alert the owner by phone calls through a series of programmable phone numbers The owner can then dial into the host to arm or disarm the alarm by using the phone s numeric keypad The Air...

Страница 6: ...arm voice message up to 10 seconds record time Telephone line disconnection alarm sounds every 5 seconds Smart 3 defense lines con guration 1st defense line is the perimeter 2nd defense line for in ro...

Страница 7: ...A Operating environment Temperature 10 50 C Humidity 80 Maximum available quantity of remote controllers 10 PCS Maximum available quantity of wireless sensors 60 PCS Dimensions 150X107X26 mm Rechargea...

Страница 8: ...t New Programming Password ENT Three Digit New Programming Password ENT __ Press PRGM button the programming LED light will come on enter 999 press ENT then input a new three digit programming passwor...

Страница 9: ...larm sound the default is 31 During the Emergency Alarm Sound is disabled or set to 30 the alarm host will operate normal and will continue to dial the enlisted phone numbers in case of emergency Alar...

Страница 10: ...is successful See Wireless Remote Controller on page 9 for more detail Arm by keyboard on alarm host Press All Alarm or Part Alarm button the alarm host will beep once to confirm the operation is succ...

Страница 11: ...After the alarm host triggered or gone off the alarm host will start to dial the first enlisted telephone number then the second third fourth and so on Unless one of the enlisted telephone numbers ans...

Страница 12: ...lay time which is default to 40 seconds or it can be change to 1 minute This means that when the system is armed you have exactly 40 seconds to exit out from the premise before the alarm trigger The d...

Страница 13: ...n detection will set off the alarm The HOME button is normally used at night This feature only responds to a perimeter breach and does not set the alarm if any of the motion sensors are triggered as y...

Страница 14: ...Wireless Smart Door Window Sensor SM 87L Functions Features Mainly detect open close states of doors and windows generally set as a 1st Defense Line or perimeters If any doors or windows are opened i...

Страница 15: ...oor window sensor featured the Smart Arm Smart Arm detect the OPEN status alert of the door window when attempting to ARM the alarm system The Smart Arm by default is enabled and dedicated for zones 0...

Страница 16: ...the door window has been opened for a short 2 second period of time and the door window is in a close status D Door is open and then immediately close after 2 second the alarm host will beep 7 times...

Страница 17: ...uccessfully cancelled The XX indicate zone number of the 1st defense line including zones 06 through 10 Note The alarm host can only learn 1 wireless device Magnet Smart Door Window Sensor at a time a...

Страница 18: ...The light will appear solid blue The XX indicate zone number of the defense line including zones 06 through 15 Step 2 Press the doorbell button twice consecutively the host alarm will beep in series a...

Страница 19: ...o 7ft above the ground Open the sensor cover and connect a 9VDC battery Next refers to the diagrams above to adjust and select the Jumper Line timer between 5S or 5MIN for the motion sensor to detect...

Страница 20: ...e B If sensing PIR detect movements after 40 seconds of exiting delay time the alarm system will trigger the sirens and sound off normally The exiting delay time of 40 seconds is the default setting a...

Страница 21: ...ecifications Operating Power 100 240VAC Wireless Receiving distance 210 ft In open area Siren Sound 105dB Installation and Usage Plug the wireless indoor siren into an electrical power outlet and wait...

Страница 22: ...ep twice to indicate the indoor siren has been successfully disarmed and the light on the siren will flash 5 times to indicate the indoor siren has been successfully added To Cancel Step 1 Connect the...

Страница 23: ...f 480 cubic feet The smoke sensor can then set off the alarm when smokes filled the photo electric cylinder chamber that is built inside the smoke sensor Once the chamber is filled with certain volume...

Страница 24: ...consumption 40 mA Working power consumption 450 mA The maximum alarm sound duration with flash 3 Minutes Receiving distance 300ft in open area Built in Rechargeable battery 6VDC 1300mA up to 100 hour...

Страница 25: ...or less than 5VDC the charging indicator solid red light will light up to represent charging The internal rechargeable battery takes approximately 20 hours to charge Activating and Deactivating Outdo...

Страница 26: ...lling Panic Button To Add Step 1 Press PRGM Password ENT 70 ENT XX ENT The light will appear solid blue The XX indicate zone number of the 24 hour defense line including zones 01 through 05 Step 2 Pre...

Страница 27: ...s Wide Angle PIR Motion Sensor Manufacturer Wireless Default Setting Wireless Sensor Type Remote Control Wireless Smart Door Window Sensor Wireless Wide Angle PIR Motion Sensor Wireless Door bell Butt...

Страница 28: ...r s manual as a reference to try to resolve this problem or simply press the star button to end the call The alarm host does not sound the alarm after the detector triggered the alarm in armed mode 1...

Страница 29: ...Adding and Cancelling sensors devicesofnewlyaddedwirelesssensor s Follow the operation instruction of Adding and Cancel ling to activate the new wireless sensor s The PIR motion sensor flashes freque...

Страница 30: ...y dusty places This is to prevent shortened lifetime of the products including the internal electronic parts and the plastic housings from being exposed to harsh conditions 3 Do not install the wirele...

Страница 31: ...be necessary if the area of installation has adequate reception However in an area with weak reception extending the antenna will provide maximum performance Q5 Does the Air Alarm support dial in to a...

Страница 32: ...SM 80 PIR Motion Sensor areas of detection is 110 degree 30x30ft It is immune to animals that are equal to or less than 10kgs in weight ie dogs cats etc 1 SM 80 can become less sensitive if the batte...

Страница 33: ...www securitymaninc com...

Отзывы: