Page.15.
To rename or delete a video, click and hold on the file until this screen appears:
(8) Video level meter
Click the icon to open the Video Level meter. The IP BUDDY+ meter can perform both NTSC and PAL video
amplitude signal measurements for PEAK to PEAK and SYNC levels. When an analog signal is fed into the meter, the tester
displays the measurements on the bottom left corner of the screen.
While in PAL format, the unit will be mV, While in NTSC format, it will be IRE.
NTSC
Video signal level
140±15IRE
Chroma level( COLOR BURST)
40±5IRE
SYNC signal level
40±5IRE
PAL
Video signal level
1000±200mV
Chroma level( COLOR BURST)
300±35mV
SYNC signal level
300±35mV