background image

v2.0  3/10/11 

4.  WIRING CONNECTIONS 

 

a.  Connect the power supply’s plug to the camera’s power outlet. 
b.  Connect the camera to the monitor with a 75

Ω

 coaxial video cable. 

c.  Connect power supply’s AC plug to a suitable AC power outlet. 
d.  Adjust the lens direction according to the required surveillance area and environment. 

 

         

     

 

          

 

 

5.  TROUBLESHOOTING 

a.  No  picture  after  applying  power  –  (i)  check  all  plugs  and  cables  are  securely 

connected  to  the  proper  connectors;  (ii)  ensure  your  power  supply  is  providing  the 
correct voltage and current. 

b.  The picture has ripples – (i) check to see if the power supply is experiencing AC ripple, 

if  so  a  filter  may  be  required;  (ii)  determine  if  the  monitor  is  faulty;  (iii)  determine  if 
other  peripheral  equipment  is  causing  ripple  and  if  so  make  the  necessary 
adjustments. 

c.  The picture background continuously changes color –  a fluorescent lamp’s magnetic 

field  may  cause  color  roll,  therefore,  reduce  the  number  of  fluorescent  lamps  or 
increase the distance between the camera and the lamps. 

d.  The picture appears smeared – (i) the power supply voltage level may be unstable, 

therefore,  try  another  power  supply;  (ii)  ensure  the  cables  are  correctly  connected 
and/or the cables are of the correct impedance. 

e.  Other interference may require a SecurityTronix ground loop isolation filter. 
f.  Additional troubleshooting assistance can be found on-line at 

www.securitytronix.com

 

in addition to support from SecurityTronix sales engineers at 1-610-429-1511. 

 

Отзывы: