18
Enter a name, password (twice), then click<Add>
. Click on the new name in the User’s list,
and
check the privileges
you wish them to have. Five categories can be selected from the
drop list.
Click <Save>
when you are finished.
<Apply><Next>
Alarm Setup Screen
NOTE: Alarm inputs for connecting the DVR to external triggering devices are optional on
some models.
Select the channe
l that you have connected a trigger device to,
select *Normal Open or
*Normal Closed, and the duration the alarm recording desired.
PTZ relate will send
instructions to a compatible PTZ camera when an alarm is triggered. Similar to motion
recording, check “Send E-mail”, and “Trigger Recording” for the channels that should respond
to the alarm, plus “Alarm Output” if you wish to trigger an external device.
*Normally Open (NO) = A switch, sensor, or other circuit that triggers an alarm when it is closed
(contacts touching).
*Normally Closed (NC) = A switch, sensor, or other circuit that triggers an alarm when it is
opened (contact separated or wire broken).
Click
<Output Schedule>
to set the hours of the day to send e-mails, for the internal buzzer to
sound, or for the alarm output to function if motion detection or an alarm input is triggered.