background image

 

ii

Important Safeguards and Warnings  

1

Electrical safety 

All installation and operation here should conform to your local electrical safety codes.  
The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited 
power source is rated 12V DC or 24V AC in the IEC60950-1. 
We assume no liability or responsibility for all the fires or electrical shock caused by improper handling 
or installation.  
We are not liable for any problems caused by unauthorized modification or attempted repair. 
 

2

Transportation security 

Heavy stress, violent vibration or water splash are not allowed during transportation, storage and 
installation. 
 

3

Installation 

Do not apply power to the camera before completing installation.  
Please install the proper power cut-off device during the installation connection. 
Always follow the instruction guide the manufacturer recommended. 
 

4

Qualified engineers needed 

 

All the examination and repair work should be done by the qualified service engineers.   
We are not liable for any problems caused by unauthorized modifications or attempted repair. 
 

5

Environment 

This series IP camera should be installed in a cool, dry place away from direct sunlight, inflammable, 
explosive substances and etc. 
Please keep it away from the electromagnetic radiation object and environment. 
Please make sure the CCD (CMOS) component is out of the radiation of the laser beam device. 
Otherwise it may result in CCD (CMOS) optical component damage. 
Please keep the sound ventilation.  
Do not allow the water and other liquid falling into the camera. 
Thunder-proof device is recommended to be adopted to better prevent thunder. 
The grounding holes of the product are recommended to be grounded to further enhance the reliability 
of the camera. 
 

6. Daily Maintenance 

Please shut down the device and then unplug the power cable before you begin daily maintenance 
work.  
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens 
surface. 

Содержание IPVD-EL3MPIR Series

Страница 1: ...HD Vandal Proof IP Dome Camera User s Manual Version 3 5 0...

Страница 2: ...our IP camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user...

Страница 3: ...fied engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair...

Страница 4: ...device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation pl...

Страница 5: ...on Combination Cable 11 2 2 Framework and Dimension 12 2 3 Bidirectional talk 13 2 3 1 Device Connection 13 2 3 2 Operation 13 2 4 Alarm Setup 13 3 Installation 15 3 1 Device Installation 15 3 2 SD Ca...

Страница 6: ...v 6 FAQ 26 Appendix Toxic or Hazardous Materials or Elements 27...

Страница 7: ...r configuration and setup in alarm or schedule setting z Support record via Web and the recorded file are storage in the client end PC z Support built in SD card z Support local SD card hot swap suppo...

Страница 8: ...s log and software version Image Sensor 1 2 8 inch CMOS Pixel 2048 H 1536 V Day Night Mode Support day night mode switch and IR CUT at the same time Auto Iris DC drive Gain Control Fixed Auto White Ba...

Страница 9: ...d Priority Manual External alarm Video detect Schedule Record and Backup Local Storage Support Micro SD card storage Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Network Protocol S...

Страница 10: ...de mode H 264B Resolution 1080P 1920 1080 720P 1280 72 0 Frame rate FPS PAL 25 NTSC 30 Bit stream type CBR Reference bit rate 3584 8192 Kb S 1536 8192Kb S Bit rate 8192 I frame interval 50 Watermark s...

Страница 11: ...le Enable Snapshot path C PictureDownload Path Record path C RecordDownload Enable Enable Main stream Encode mode G 711A Enable Disable Audio Sub Extra stream Encode mode G 711A Host name IPC Ethernet...

Страница 12: ...er type Disable CN99 DDNS Server IP none Port 80 Domain name none User name none Password N A DDNS Update period 10m IP filter Trusted sites Disable SMTP server none Port 25 Anonymity Disable User nam...

Страница 13: ...ulticast Port 36666 WIFI On Enable Enable Real time monitor 0 Wireless QoS Parameter Disable QoS Command 0 Enable Disable Anti dither 5 seconds Sensitivity 3 Record Channel Enable Record Delay 10 seco...

Страница 14: ...ay Alarm activation Snapshot Disable Alarm setup Relay Alarm output 1 Enable Disable Relay Alarm output Enable Relay output delay 10s No SD card Send email Disable Enable Disable Capacity limit Space...

Страница 15: ...anonymous Password N A Remote storage path share Destination Storag e FTP Emergency storage to local path Disable Pack duration 8m Pre record 5s Disk full Overwrite Record mode Auto Storage managemen...

Страница 16: ...Week Start time 00 00 00 of the first Sunday of the month End time 00 00 00 of the second Monday of the month Synchronize with NTP Disable NTP server clock isc org Port 37 Update period 10m Auto reboo...

Страница 17: ...the video AUDIO IN Audio input port RCA Input audio signal It can receive the analog audio signal from the pickup AUDIO OUT Audio output port RCA Output audio signal to the devices such as the sound...

Страница 18: ...NO normal open alarm output port 3 ALARM_IN1 Alarm input port 1 It is to receive the on off signal from the external alarm source 4 ALARM_IN2 Alarm input port 2 It is to receive the on off signal fro...

Страница 19: ...al talk 2 4 Alarm Setup The alarm interface is shown as in Figure 2 4 Please follow the steps listed below for local alarm input and output connection 1 Connect the alarm input device to the alarm inp...

Страница 20: ...14 Figure 2 4...

Страница 21: ...d below 3 1 Device Installation Step 1 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome cover and then open the cover The device is shown as in Figure 3 1 Fi...

Страница 22: ...hree holes of the installation position Put the three inner hexagon screws into the screw holes at the bottom of the pedestal Use the inner hexagon screwdriver to fix firmly Connect the GND to the gro...

Страница 23: ...igure are the optical adjustment component Please make sure it is outward and do not allow it to touch the X Y Z axis module See Figure 3 5 Figure 3 5 Step 7 Put the dome cover back and then put the t...

Страница 24: ...R light Figure 3 7 3 3 Lens Adjustment Step 1 Slightly loose the screw B manually and then turn the screw B slowly Adjust the lens focus distance to the proper position according to the monitor video...

Страница 25: ...19 With IR light Without IR light Figure 3 8...

Страница 26: ...y applies to the IP addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view devic...

Страница 27: ...terface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 4 In Figure 4 4 you can view device IP address user name password and port Please modi...

Страница 28: ...22 Figure 4 5...

Страница 29: ...mask and gateway of the PC and the IPC respectively IPC default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection...

Страница 30: ...se click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have inst...

Страница 31: ...25 Figure 5 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Страница 32: ...k When network upgrade operation failed you can use port 3800 to continue upgrade Recommended SD card brand Kingston 4GB Kingston 1GB Kingston 16GB Transcend 16GB SanDisk 1G SanDisk 4G 32GB Class4 Usu...

Страница 33: ...he environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not res...

Отзывы: