Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
71
Configure Wiegand Code Scheme
These procedures will configure the scheme to be followed for Wiegand codes. Wiegand codes can
be set to exist as standard keypad codes as well or to be kept separate on a different list.
IMPORTANT! COMPLETING THESE PROCEDURES WILL DELETE ALL WIEGAND CODES!
Wiegand Input 1
1251
$
6
$
1
$
504
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 1 (for Wiegand Input 1). No tone will sound.
Enter secondary sub mode 504 and listen for good tone.
Enter 1 (for same as keypad codes) or 2 (for different codes) and listen for good tone.
Enter # to exit Programming Mode.
Wiegand Input 2
1251
$
6
$
2
$
504
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 2 (for Wiegand Input 2). No tone will sound.
Enter secondary sub mode 504 and listen for good tone.
Enter 1 (for same as keypad codes) or 2 (for different codes) and listen for good tone.
Enter # to exit Programming Mode.
Both Wiegand Inputs
1251
$
6
$
3
$
504
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 3 (for both Wiegand inputs). No tone will sound.
Enter secondary sub mode 504 and listen for good tone.
Enter 1 (for same as keypad codes) or 2 (for different codes) and listen for good tone.
Enter # to exit Programming Mode.
Note: These procedures will not work if any of the following are true:
Wiegand input is disabled.
Split relay feature is enabled.
Содержание Edge 27-210