Securiton SecuriFire B6-PSU Скачать руководство пользователя страница 3

Imprint 

 

B6-PSU Power Supply Unit, Technical Description, T 811 039 en a 

3 / 18 

Imprint 

 

Notice 

This document, T 811 039, is valid only for the product described in Section 1. 

This document is subject to change or withdrawal without prior notice. The validity of the statements made in this 
document applies until the statements are revised by a new edition of the document (T number with new index). 
The  user  of  this  document  is  responsible  for  staying  up  to  date  with  its  current  status  through  the  edi-
tor/publisher.  We  accept  no  responsibility  for  claims  against  any  incorrect  statements  in  this  document  which 
were unknown to the publisher at the time of publication. Handwritten changes and additions are not valid. This 
document is protected by copyright. 

Foreign language documentation as listed in this document is always released or changed at the same time as 
the German edition. If there are inconsistencies between the foreign language documentation and the German 
documentation, the German documentation is binding. 
Some words in this document are highlighted in 

blue

. These are terms and designations which are the same in 

all languages and are not translated. 

Users are encouraged to contact the editor/publisher if there are statements which are unintelligible, misleading, 
incorrect, or if there are errors. 

© Securiton AG, Alpenstrasse 20, 3052 Zollikofen, Switzerland 

 
 
This document, T 811 039

1

, is available in the following languages: 

German T 811 039 de 

 

English  T 811 039 en 

 

French  T 811 039 fr 

 
 
Current edition: 

Index a 

08.06.2012 

Rd 

 
 
 
 

                                                           

1

 Reference document: B6-PSU, V 1.1 

 

Содержание SecuriFire B6-PSU

Страница 1: ...Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 811 039 en a SecuriFire Power Supply Unit B6 PSU Technical Description ...

Страница 2: ......

Страница 3: ... and additions are not valid This document is protected by copyright Foreign language documentation as listed in this document is always released or changed at the same time as the German edition If there are inconsistencies between the foreign language documentation and the German documentation the German documentation is binding Some words in this document are highlighted in blue These are terms...

Страница 4: ...erted Other safety relevant information Warning The product may be damaged if the safety information is not heeded Description of which damage can occur Measures and preventative actions How dangers can be averted Other safety relevant information Notice The product may malfunction if this notice is not observed Description of which malfunctions can be expected Measures and preventative actions Ot...

Страница 5: ... Technical Description T 811 039 en a 5 18 Document history First edition Date 01 July 2011 Index a Date 08 06 2012 Most important changes compared with first edition Section New n changed c deleted d What Reason 7 n Article SI G 8A complement ...

Страница 6: ......

Страница 7: ...tion 13 3 3 Battery current measurement 13 _________________________________________________________________________________________ 4 Displays 14 4 1 Fault displays 14 4 2 LED displays 14 _________________________________________________________________________________________ 5 Technical data 15 5 1 Mains input 15 5 2 Direct current voltage inputs outputs 15 5 2 1 Battery connection 15 5 2 2 Out...

Страница 8: ......

Страница 9: ...The B6 PSU supplies the required output voltage of 3 3 V 5 V and 27 V to each SecuriFire 1000 2000 In the event of mains failure the standards compliant battery buffered DC voltage for the SCP and peripheral devices must be ensured This is accomplished by connecting two or four batteries of a type which has been tested by VdS and approved by Securiton AG The batteries are connected on the bottom s...

Страница 10: ...tion X3 Connector for battery current measurement X4 Output voltage for internal consumers X5 Output voltage for external consumers X13 VBAT battery connection X14 GNDBAT battery connection S1 On Off switch mains switch V45 LED displays A10 Output fuses F1 to F5 V45 X4 X4 S1 X3 A10 X1 X14 X5 X13 Fig 2 B6 PSU interfaces ...

Страница 11: ... sources of energy If there is a mains voltage or mains power supply fail ure the internal batteries automatically supply the system with power 2 4 Connection One battery pair 15 18 Ah is connected to the B6 PSU by default in a SecuriFire 1000 2000 From building distributor Fuse at least 10 A Own FI switch Bayonet fuse L1 N PE BATTERY 12V 15 17Ah 8A 8A B6 PSU 5V 3 3V NETOK EIN AUS 50mV A F5 F4 F1 ...

Страница 12: ...teries by the integrated protection circuit When this happens only the battery charging current and not the sys tem supply current is interrupted this guarantees the uninterruptible power supply of the system even if the batteries are faulty The criterion for disablement of the charging current is a battery undervoltage of approx 18 V When the battery charging branch is disabled the system voltage...

Страница 13: ...esults of the battery current measurement example with a 18 Ah battery pair is not in line with the power requirement calculation 5 notify your Securiton Support point immediately Observe the following procedure precisely During normal operation remove the mains plug of the B6 PSUB6 PSU power supply unit of the SecuriFire 1000 2000 there must be no pending alarms or disablements the batteries must...

Страница 14: ...in preparation 4 2 LED displays The B6 PSU Power Supply Unit has two LED displays on the front side which indicate the current state of the board Display for Status Meaning NET OK On Mains voltage present Off No mains voltage present overtemperature 5 V 3 3 V On All system voltages 27 V 5 V 3 3 V are present Off At least one system voltage is lacking power supply unit switched off Notice The NET O...

Страница 15: ... voltage dependent on temperature U 0 C 28 3 V 1 U 50 C 26 3 V 1 At X C and X C stored device without load or battery charging current within 1 min after switching on 28 42 X 2 50 V 0 2 Temperature dependent Linear Load current limit 3 19 A 7 for I 0 A Residual ripple without batteries Effective residual ripple voltage 100 mV for full charging current Minimum voltage for battery test 20 2 V Batter...

Страница 16: ... X5 PIN 2 F5 Idle voltage when batteries disabled 29 V 2 Current limit when batteries not connected sum of all outputs when 5 V and 3 3 V circuits not loaded 4 A 1 for Uout 24 V Residual ripple without batteries Acc to VDE 0878 Class B Idle voltage when batteries full U 0 C 28 3 V 1 U 50 C 26 3 V 1 Typical output resistance static when I 0 75 A sum of all outputs with parallel connection of all ou...

Страница 17: ...en batteries full U 0 C 28 3 V 1 U 50 C 26 3 V 1 Typical static output resistance when Ia 0 5 A when Ta 25 300 mΩ Notice The F4 polymer fuse on the B6 PSU is a self healing fuse It resets itself after a short circuit as soon as electrical current no longer flows through it it can therefore be used many times Output voltage 5 06 V 2 7 Output current 0 mA 1 A Output ripple 50 mV measurement bandwidt...

Страница 18: ... VDE 0800 Telecommunications Security VDE 0804 Telecommunications Additional definitions VDE 0833 Alarm systems for fire intrusion and hold up VDE 0878 Cl B Radio interference suppression of telecommunication equipment VdS 2110 Schutz gegen Umwelteinflüsse VdS 2115 Energieversorgungsgeräte Anforderungen VdS 2541 Energieversorgungseinrichtungen 7 Article numbers spare parts Short designation Swiss ...

Отзывы: